The Success and Failure of a Radiology Quality Metric: The Case of OP-10
C Craig Blackmore1, Douglas Watt2, Paul L Sicuro2
1Department of Radiology, Virginia Mason Medical Center, Seattle, Washington; Center for Health Care Improvement Science, Virginia Mason Medical Center, Seattle, Washington.
Purpose:
Medical quality metrics can serve various functions, including promoting quality improvement efforts within a medical system, and providing a basis for comparing quality among institutions. OP-10, an imaging efficiency quality measure based on the number of CT scans of the abdomen performed both with and without contrast is broadly used and publically reported, but it has not been investigated in actual practice.
Methods:
In this project, we report on both a successful quality improvement effort built around measurement of OP-10, and on the identified potential limitations of OP-10 itself for comparing among institutions. We performed two quality improvement interventions in 2012 and 2014 directed at OP-10, encompassing building of institutional practice standards via creating multidisciplinary consensus, educating radiologists and clinicians, revising CT protocols, and providing performance measurement and feedback. Results were extracted from the radiology information system and analyzed using interrupted time series segmented regression and statistical process control charts.
Results:
The proportion of inappropriate abdominal CT scans with and without contrast under OP-10 decreased, from 3,041 of 13,855 (21.9%) to 691 of 6,006 (11.5%) (P < .0001). However, 262 of 691 (37.8%) of the CT scans labeled as potential overuse by OP-10 could be considered appropriate under national guidelines. These discordant cases clustered in specific clinical areas (eg, urology and hepatology), indicating potential for bias against centers that serve referral populations in these areas.
Conclusions:
We conclude that OP-10 can be useful to drive internal quality improvement efforts but is potentially biased when used for interinstitutional comparisons.
Related Concept Videos
Methods of Documentation II: POMR
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Quality Assurance
Receiver Operating Characteristic Plot
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation I: X-ray and CT