Related Experiment Video
Updated: Mar 25, 2026

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Dissolution of a mineral trioxide aggregate sealer in endodontic solvents compared to conventional sealers
Hanan Alzraikat1, Nessrin Ahmad Taha1, Layla Hassouneh1
1Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan.
Abstract:
The aim of this study is to evaluate the solubility of a Mineral Trioxide Aggregate sealer (MTA-Fillapex) compared with five other sealers, calcium hydroxide (Sealapex), resin (Realseal), zinc oxide-eugenol (Tubli-Seal), and two epoxy resins (AH-26 and AH-Plus), in chloroform and eucalyptoil in static and ultrasonic environments. Samples of each sealer were prepared (n = 180) and then divided into 12 groups that were immersed in solvents for 5 and 10 min in static and ultrasonic environments. The mean weight loss was determined, and the values were compared using Student's t-test, One-way ANOVA, and Tukey's HSD post-hoc test (p < 0.05). In chloroform, MTA-Fillapex, AH-26, and Sealapex displayed moderate solubility with no significant difference in dissolution (p = 0.125); however, their dissolution was significantly lower than that of AH-Plus (p < 0.001), which was almost fully dissolved after 10 minutes. Realseal was significantly less soluble than all sealers (p < 0.001). In eucalyptoil, MTA-Fillapex showed low solubility, as all of the sealers did, but Tubli-Seal was significantly more soluble than other sealers (p < 0.001). Using ultrasonic activation resulted in a significantly higher dissolution rate in chloroform for all sealers except MTA-Fillapex after 10 min (p = 0.226). In eucalyptoil, ultrasonic activation significantly increased the dissolution rate of all sealers except MTA-Fillapex after 5 and 10 min, Sealapex at 10 min, and AH-Plus at 5 min (p > 0.05). In conclusion, MTA-Fillapex was not sufficiently dissolved in either solvent. Ultrasonic activation had limited effectiveness on MTA-Fillapex dissolution, whereas it significantly increased the efficiency of solvents in dissolving a number of endodontic sealers.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
Related Concept Videos
Titration in Nonaqueous Solvents
Solvating Effects
In Vitro Drug Dissolution: Alternative Methods
Solvents
A...