Related Experiment Video
Updated: Mar 25, 2026

Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
Do CAS measurements correlate with EOS 3D alignment measurements in primary TKA?
Marrigje F Meijer1, Alexander L Boerboom2, Sjoerd K Bulstra2
1Department of Orthopaedics, University of Groningen, University Medical Center Groningen, PO Box 30.001, 9700 RB, Groningen, The Netherlands. m.f.meijer@umcg.nl.
Computer-assisted surgery (CAS) alignment measurements in total knee arthroplasty (TKA) differ from EOS 3D reconstructions, raising concerns about CAS validity and reliability in TKA procedures.
Area of Science:
- Orthopedic surgery
- Medical imaging technology
- Biomechanical analysis
Background:
- Accurate coronal alignment is crucial for successful total knee arthroplasty (TKA).
- Computer-assisted surgery (CAS) is increasingly used for intraoperative guidance.
- EOS 3D reconstructions offer a precise method for preoperative and postoperative alignment assessment.
Purpose of the Study:
- To compare intraoperative CAS alignment measurements with pre- and postoperative EOS 3D coronal alignment measurements in TKA.
- To evaluate the accuracy and reliability of CAS systems in TKA procedures.
Main Methods:
- A prospective study involving 56 TKAs using imageless CAS.
- Coronal alignment measurements taken intraoperatively with CAS (pre-bone cut and post-implantation).
- Pre- and postoperative alignment measured using EOS 3D reconstructions, eliminating acquisition errors.
Main Results:
- Significant differences observed in varus/valgus (VV) angles between CAS and EOS measurements.
- Preoperative mechanical lateral distal femoral angle (mLDFA) showed no significant difference.
- CAS measured significantly more valgus for mechanical medial proximal tibial angle (mMPTA) preoperatively compared to EOS.
Conclusions:
- Discrepancies between CAS and EOS measurements are attributed to weight-bearing differences and potential CAS validity/reliability issues.
- EOS 3D may overestimate VV angle in cases with significant mechanical axis deviation.
- CAS tends to measure more valgus than EOS for minor axis deviations and mMPTA, impacting clinical relevance and raising concerns about CAS system reliability in TKA.
More Related Videos
08:15Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025