Effect of Oxygenator Size on Air Removal Characteristics: A Clinical Evaluation
Marco C Stehouwer1, Roel de Vroege, Johannes C Kelder
1From the *Department of Extracorporeal Circulation, St Antonius Hospital, Nieuwegein, The Netherlands; †Department of Extracorporeal Circulation, HAGA Hospital, The Hague, The Netherlands; ‡Department of Cardiology, St Antonius Hospital, Nieuwegein, The Netherlands; §Department of Cardiothoracic Surgery, St Antonius Hospital, Nieuwegein, The Netherlands; ¶Section Cardiovascular Biomechanics, Faculty of Biomedical Technology, Technical University Eindhoven, Eindhoven, The Netherlands; and ‖Department of Anaesthesiology, Intensive Care and Pain Management, St Antonius Hospital, Nieuwegein, The Netherlands.
Abstract:
During cardiopulmonary bypass (CPB), gaseous microemboli (GME) are released into the patients' arterial bloodstream. Gaseous microemboli may contribute to the adverse outcome after cardiac surgery. Recently, two oxygenator models with or without integrated arterial filter (IAF) were designed and only differ in size, leading to a change of 20% in surface area of the hollow fibers and 25% in blood velocities. The aim of this study was to assess the air removal characteristics of the inspire oxygenators with or without IAF. Sixty-eight patients were randomly assigned to four different groups: optimized adult and full adult and an additional IAF. Gaseous microemboli reduction rates were measured with a bubble counter. The number of GME reduction rates showed no differences. However, both models reduced significantly less volume of GME (optimized adult: 40.6% and full adult: 50.3%) compared with both models with IAF (88.7% and 88.5%, respectively). No significant differences of reduction rates were found between both devices without IAF and also not between both models with IAF. In conclusion, the larger inspire oxygenator tends to remove more GME. No effect from size of oxygenator device with integrated screen filter on GME reduction was observed. The inspire oxygenators with IAF may be considered as an adequate GME filter.
Related Concept Videos
Bioreactor Controls-II
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Transport in the Blood
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...