Related Experiment Video
Updated: Mar 25, 2026

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Volumetric multislice gagCEST imaging of articular cartilage: Optimization and comparison with T1rho
Feliks Kogan1, Brian A Hargreaves1,2,3, Garry E Gold1,2,4
1Department of Radiology, Stanford University, Stanford, California, USA.
Purpose:
To develop and optimize a multislice glycosaminoglycan (GAG) chemical exchange saturation transfer (GagCEST) sequence for volumetric imaging of articular cartilage, and to validate the sequence against T1ρ relaxation times in whole joint imaging of tibiotalar cartilage.
Methods:
Ex vivo experiments were used to observe the effect of the number of partitions and shot TR on signal-to-noise ratio and measured GagCESTasym . GagCEST imaging of the entire tibiotalar joint was also performed on 10 healthy subjects. The measured GagCESTasym was compared and correlated with T1ρ relaxation times.
Results:
Ex vivo studies showed a higher average GagCESTasym from articular cartilage on multislice acquisitions acquired with two or more partitions than observed with a single-slice acquisition. In healthy human subjects, an average GagCESTasym of 8.8 ± 0.7% was observed. A coefficient of variation of GagCESTasym across slices of less than 15% was seen for all subjects. Across subjects, a Pearson correlation coefficient of -0.58 was observed between the measured gagCESTasym and T1ρ relaxation times.
Conclusions:
We demonstrated the feasibility and optimization of multislice GagCEST mapping of articular cartilage. Volumetric analysis and decreased scan times will help to advance the clinical utility of GagCEST imaging of articular cartilage. Magn Reson Med 77:1134-1141, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
07:57An Experimental and Finite Element Protocol to Investigate the Transport of Neutral and Charged Solutes across Articular Cartilage
Published on: April 23, 2017
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging