Effects of Icodextrin and Glucose Bicarbonate/Lactate-Buffered Peritoneal Dialysis Fluids on Effluent Cell Population

Sylvie Opatrná1,2, Anna Pöpperlová1,2, Daniel Lysák2,3

  • 1Departments of Medicine I, Charles University Medical School and Teaching Hospital Plzen, Plzen, Czech Republic.

Icodextrin peritoneal dialysis (PD) solution has been shown to increase interleukin-6 (IL-6) levels in PD effluent as well as leukocyte and mesothelial cell count. Mesothelial cells release cancer antigen 125 (CA125), which is used as a marker of mesothelial cell mass. This 1-year prospective study was designed to compare peritoneal effluent cell population, its inflammatory phenotype and biocompatibility biomarkers IL-6 and CA125 between icodextrin (E) and glucose bicarbonate/lactate (P) based PD solutions. Using baseline peritoneal ultrafiltration capacity, 19 stable incident PD patients were allocated either to P only (N = 8) or to P plus E for the overnight dwell (N = 11). Flow cytometry was used to measure white blood cell count and differential and the expression of inflammatory molecules on peritoneal cells isolated from timed overnight peritoneal effluents. Compared to P, E effluent showed higher leukocyte (10.9 vs. 7.9), macrophages (6.1 vs. 2.5) and mesothelial cells (0.3 vs. 0.1)×10(6) /L count, as well as expression of HLA DR on mesothelial cells and IL-6 (320.5 vs. 141.2 pg/min) on mesothelial cells and CA125 appearance rate (159.6 vs. 84.3 IU/min), all P < 0.05. In the E group, correlation between IL-6 and CA125 effluent levels (r = 0.503, P < 0.05) as well as appearance rates (r = 0.774, P < 0.001) was demonstrated. No effect on systemic inflammatory markers or peritoneal permeability was found. Icodextrin PD solution activates local inflammation without systemic consequences so the clinical relevance of this observation remains obscure. Correlation between effluent IL-6 and CA125 suggests that CA125 might be upregulated due to inflammation and thus is not a reliable marker of mesothelial cell mass and/or biocompatibility.

Related Concept Videos

Peritoneal Dialysis I: Introduction and Procedure01:30

Peritoneal Dialysis I: Introduction and Procedure

Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
5.9K
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications01:25

Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications

Peritoneal dialysis (PD) is a medical process that removes waste products and excess fluid from the body using the peritoneal membrane as a natural filter.Peritoneal Dialysis MethodsSeveral methods can be used for peritoneal dialysis, including Acute Intermittent Peritoneal Dialysis, Continuous Ambulatory Peritoneal Dialysis, and Automated Peritoneal Dialysis, also known as Continuous Cyclic Peritoneal Dialysis.Acute Intermittent Peritoneal Dialysis (AIPD) is used for patients with uremic...
1.5K
Peritoneal Dialysis III: Nursing Management01:25

Peritoneal Dialysis III: Nursing Management

Peritoneal dialysis, or PD, utilizes the peritoneal membrane as a filter to eliminate excess fluid and waste products. Effective nursing management is essential for ensuring patient safety, preventing complications, and promoting optimal function of the peritoneal dialysis process.Assessment and MonitoringNurses must thoroughly assess the patient before, during, and after each dialysis session. Regular monitoring includes vital signs, daily weight, fluid intake and output, and laboratory values...
1.3K
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.1K
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
1.9K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.7K