Related Experiment Video
Updated: Mar 24, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Screw Joint Stability in Conventional and Abutment-Free Implant-Supported Fixed Restorations
Purpose:
Procera Implant Bridges (PIBs) do not engage supporting implant shoulders and are fixed using comparably long retention screws. The aim of this in vitro clinical study was to determine the detorque values in PIBs and conventionally fabricated fixed dental prostheses (FDPs).
Materials And Methods:
Two groups of screw-retained implant-supported three-unit FDPs (n=10) were fabricated by means of conventional casting or computer-aided design/computer-assisted manufacture to fit an in vitro situation with two implants. Following fixation, the restorations were subjected to masticatory simulation (100,000 cycles, 100 N) and subsequent detorquing of the retention screws. In the clinical part, a total of 10 patients received PIB restorations in the premolar/molar region that were detorqued after 2, 4, and 6 months. One-sample t tests adjusted for multiple testing by the Bonferroni-Holm method were applied for statistical analysis based on percentage detorque values (α=.05).
Results:
60% of the initial torque values were maintained in screws directly retaining restorations, while the abutment screws used in the conventional restorations showed detorque levels in the range of 80%. No significant difference in detorque levels between screws retaining PIBs and conventional FDPs could be detected (P=.5186). The abutment screws showed significantly greater detorque values compared with screws directly retaining restorations (P=.0002; P=.0000). In vivo, a significant increase in detorque values ranging from 21.64 Ncm after 2 months to 27.81 Ncm after 6 months was recorded.
Conclusion:
Prosthetic screws retaining implant-supported FDPs show torque loss during the initial period of service. Retightening reduces the amount of future torque loss.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
10:42A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Method of Joints: Problem Solving II