Amplifying and Quantifying HIV-1 RNA in HIV Infected Individuals with Viral Loads Below the Limit of Detection by Standard Clinical Assays
Published on: September 26, 2011
Human Immunodeficiency Virus Diagnostic Testing: 30 Years of Evolution
1Summa Health, Department of Pathology and Laboratory Medicine, Akron, Ohio, USA, and Northeast Ohio Medical University, Rootstown, Ohio, USA alexandt@summahealth.org.
A concern during the early AIDS epidemic was the lack of a test to identify individuals who carried the virus. The first HIV antibody test, developed in 1985, was designed to screen blood products, not to diagnose AIDS. The first-generation assays detected IgG antibody and became positive 6 to 12 weeks postinfection. False-positive results occurred; thus, a two-test algorithm was developed using a Western blot or immunofluorescence test as a confirmatory procedure. The second-generation HIV test added recombinant antigens, and the third-generation HIV tests included IgM detection, reducing the test-negative window to approximately 3 weeks postinfection. Fourth- and fifth-generation HIV assays added p24 antigen detection to the screening assay, reducing the test-negative window to 11 to 14 days. A new algorithm addressed the fourth-generation assay's ability to detect both antibody and antigen and yet not differentiate between them. The fifth-generation HIV assay provides separate antigen and antibody results and will require yet another algorithm. HIV infection may now be detected approximately 2 weeks postexposure, with a reduced number of false-positive results.
A concern during the early AIDS epidemic was the lack of a test to identify individuals who carried the virus. The first HIV antibody test, developed in 1985, was designed to screen blood products, not to diagnose AIDS. The first-generation assays detected IgG antibody and became positive 6 to 12 weeks postinfection. False-positive results occurred; thus, a two-test algorithm was developed using a Western blot or immunofluorescence test as a confirmatory procedure. The second-generation HIV test added recombinant antigens, and the third-generation HIV tests included IgM detection, reducing the test-negative window to approximately 3 weeks postinfection. Fourth- and fifth-generation HIV assays added p24 antigen detection to the screening assay, reducing the test-negative window to 11 to 14 days. A new algorithm addressed the fourth-generation assay's ability to detect both antibody and antigen and yet not differentiate between them. The fifth-generation HIV assay provides separate antigen and antibody results and will require yet another algorithm. HIV infection may now be detected approximately 2 weeks postexposure, with a reduced number of false-positive results.
More Related Videos
11:19Pairwise Growth Competition Assay for Determining the Replication Fitness of Human Immunodeficiency Viruses
Published on: May 4, 2015
14:23A Restriction Enzyme Based Cloning Method to Assess the In vitro Replication Capacity of HIV-1 Subtype C Gag-MJ4 Chimeric Viruses
Published on: August 31, 2014
Related Concept Videos
Viral Mutations
Retrovirus Life Cycles
Sexually Transmitted Infections