Related Experiment Video
Updated: Mar 24, 2026

Ultrasound Assessment of Endothelial-Dependent Flow-Mediated Vasodilation of the Brachial Artery in Clinical Research
Published on: October 22, 2014
A Comparison of Measures of Endothelial Function in Patients with Peripheral Arterial Disease and Age and Gender
Richard B Allan1, Simon V Vun1, J Ian Spark1
1Department of Vascular and Endovascular Surgery, Flinders University, Bedford Park, SA 5042, Australia; Department of Vascular and Endovascular Surgery, Flinders Medical Centre, Bedford Park, SA 5042, Australia.
Abstract:
This study compared flow-mediated dilatation (FMD), peripheral artery tonometry (PAT), and serum nitric oxide (NO) measures of endothelial function in patients with peripheral artery disease (PAD) against age/gender matched controls. 25 patients (mean age: 72.4 years, M : F 18 : 7) with established PAD and an age/gender matched group of 25 healthy controls (mean age: 72.4 years, M : F 18 : 7) were studied. Endothelial function was measured using the % FMD, reactive hyperemia index (RHI) using PAT and serum NO (μmol). Difference for each method between PAD and control patients and correlation between the methods were investigated. FMD and RHI were lower in patients with PAD (median FMD for PAD = 2.16% versus control = 3.77%, p = 0.034 and median RHI in PAD = 1.64 versus control = 1.92, p = 0.005). NO levels were not significantly different between the groups (PAD median = 7.70 μmol, control median = 13.05 μmol, p = 0.662). These results were obtained in elderly patients and cannot be extrapolated to younger individuals. FMD and PAT both demonstrated a lower hyperaemic response in patients with PAD; however, FMD results in PAD patients were unequivocally reduced whereas half the PAD patients had RHI values above the established threshold for endothelial dysfunction. This suggests that FMD is a more appropriate method for the measurement of NO-mediated endothelial function.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Peripheral Artery Disease I: Introduction
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...

