Natalie Ebert1, Pierre Delanaye2, Michael Shlipak3
1Charité University Medicine, Institute of Public Health, Berlin, Germany.
Background:
Cystatin C is increasingly used in glomerular filtration rate (GFR) estimation equations. The dependence of cystatin C results upon the analytical method has been a major source of controversy.
Methods:
Cystatin C was measured with non-standardized turbidimetric Roche Generation 1 and standardized nephelometric Siemens assays in 3666 and additionally with standardized Roche Generation 2 and Siemens in 567 blood samples of the Berlin Initiative Study. Cystatin C-based GFR was assessed with CKD-EPIcys (Chronic Kidney Disease Epidemiology) and CAPA (Caucasian, Asian, Pediatric, Adult) equations and the impact of the assays on GFR estimation was determined. Equation performance compared to measured GFR was evaluated.
Results:
Concordance of Roche Gen2 and Siemens was high with median difference of 0.003 ± 0.13 mg/L (limits of agreement: -0.12 to 0.12) and Passing Bablok correlation was essentially perfect. Roche Gen1 assay showed worse concordance with Siemens: median difference was 0.08 ± 0.13 mg/L (limits of agreement: -0.18 to 0.34) and correlation was inferior. Mean difference (± SD) of estimated GFRCKD-EPIcys was 0 ± 4 mL/min/1.73 m(2) for Gen2 and Siemens compared to -5 ± 8 with Gen1. Performance of GFR estimating equations was not influenced by the choice of Siemens or Gen2 assays.
Conclusions:
Standardization of Roche Gen2 assay improved accuracy of cystatin C measurement compared to Siemens. It suggests only negligible method bias and results in equal performance of both assays when estimating GFR indicating that successful calibration has led to major progress in cystatin C analysis.
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Serum Studies: Renal Function Tests
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...