Related Experiment Video
Updated: Mar 24, 2026

Author Spotlight: Standardizing the Development of Amine-Based Silica Composites as CO2 Adsorbents for Direct Air Capture
Published on: September 29, 2023
Implementation and evaluation of an analytical method for a novel derivatizing agent to measure 4,4'-methylene
Silvia Puscasu1, Simon Aubin1, Mark Spence2
1a Institut de recherche Robert-Sauvé en santé et en sécurité du travail , Montréal , Québec , Canada.
Abstract:
Accurate measurement of 4,4'-methylene diphenyl diisocyanate (MDI) atmospheres is a challenge since the molecule is both chemically reactive and likely to be present in aerosol form when heated and sprayed because of its low vapor pressure. Meeting this challenge requires optimizing both the sampling device used and the derivatization agent employed to stabilize the isocyanate functional group. This study describes the use of a novel derivatization reagent for isocyanate sampling to address the challenge of MDI aerosol exposure sampling. Like most conventional derivatizing agents for isocyanates, 1,8-diaminonapthalene (DAN) reacts with isocyanate functional groups to form a urea. However, unlike other isocyanate derivatizing agents, the sample workup procedure with DAN includes a second step which yields a single analyte molecule, perimidone, for each isocyanate group. This feature gives DAN the unique ability to assess exposure to "total reactive isocyanate group" (TRIG). The analytical method implemented to quantitate the perimidone uses liquid chromatography coupled with tandem mass spectrometry. Positive mode ionization led to LOD and LOQ of 10 ng/mL and 34 ng/mL, respectively. The dynamic range was from 50-2000 ng/mL (with R(2) ≥ 0.990), which corresponds to TRIG concentrations in air from 0.07-3.04 µg/m(3), assuming 60 min of sampling at 10 L/min (based on use of the CIP-10M sampler). The intra-day and inter-day analytical precisions were <4% for all of the concentration levels tested, and the accuracy was within an appropriate range of 98 ± 2%. Minimal matrix effect was observed, and a total recovery of 109% was obtained. The approach seems to be promising for TRIG measurements and further work is planned to establish DAN method behavior in samplers used for workplace monitoring.
Related Concept Videos
Carboxylic Acids to Methylesters: Alkylation using Diazomethane
Chemical Ionization (CI) Mass Spectrometry
Olefin Metathesis Polymerization: Acyclic Diene Metathesis (ADMET)
Similar to cross-metathesis, ADMET also involves the formation of metallacyclobutane intermediate by [2+2] cycloaddition of one of the double bonds of a terminal diene with...
Stability of Conjugated Dienes
A comparison of the enthalpies of hydrogenation of dienes reveals that conjugated dienes release less heat on hydrogenation, rendering them more stable than their nonconjugated analogs.
π Molecular Orbitals of 1,3-Butadiene
The simplest conjugated diene is 1,3-butadiene: a four-carbon system where each carbon is sp2-hybridized and has an unhybridized p orbital that contains an unpaired electron. According to molecular orbital theory, atomic orbitals combine to form molecular orbitals such that the number...
[4+2] Cycloaddition of Conjugated Dienes: Diels–Alder Reaction