Differential displacement of soft tissue layers from manual therapy loading
Shawn Engell1, John J Triano2, James R Fox3
1Rehabilitation Science, McMaster University, Hamilton, Ontario, Canada.
Background:
Understanding the biomechanics of spinal manipulative therapy requires knowing how loads are transmitted to deeper structures. This investigation monitored displacement at sequential depths in thoracic paraspinal tissues parallel with surface load directions.
Methods:
Participants were prone and a typical preload maneuver was applied to thoracic tissues. Ultrasound speckle tracking synchronously monitored displacement and shear deformation of tissue layers in a region of interest adjacent to load application to a depth of 4 cm. Cumulative and shearing displacements along with myoelectric activity were quantitatively estimated adjacent to loading site.
Findings:
The cephalocaudal cumulative displacement in layers parallel to the surface were, in order of depth, 1.27 (SD=0.03), 1.18 (SD=0.02), and 1.06 (SD=0.01) mm (P<0.000), respectively. The superficial/intermediate shear was 2.1 ± 2.3% whereas the intermediate/deep shear was 4.4% (SE=3.7, P=0.014). Correlation of tissue layers was stronger with application site displacement at the surface (0.87
Interpretation:
Surface loading of the torso in combined posteroanterior and caudocephalic directions result in both displacement of tissues anteriorly and in shearing between tissue layers in the plane of the tissues strata to depths that could plausibly affect spinal tissues. Displacements of tissues more likely arise passively, consistent with load transmitted by the retinacula cutis and epimuscular force pathways. Displacements are similar in magnitude to those known to evoke biologically relevant responses in both animal and human studies.
More Related Videos
07:34Layer Microdissection of Tricuspid Valve Leaflets for Biaxial Mechanical Characterization and Microstructural Quantification
Published on: February 10, 2022
06:26Stereo-Imaging System DLT Calibration to Capture 3D In Situ Displacements of Stretched Peripheral Nerves
Published on: January 12, 2024
Related Concept Videos
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Ultrasonography
During an ultrasonography procedure, a handheld device called...