A novel method for correcting scanline-observational bias of discontinuity orientation
Lei Huang1, Huiming Tang1,2, Qinwen Tan1
1Faculty of Engineering, China University of Geosciences, Wuhan 430074, China.
Abstract:
Scanline observation is known to introduce an angular bias into the probability distribution of orientation in three-dimensional space. In this paper, numerical solutions expressing the functional relationship between the scanline-observational distribution (in one-dimensional space) and the inherent distribution (in three-dimensional space) are derived using probability theory and calculus under the independence hypothesis of dip direction and dip angle. Based on these solutions, a novel method for obtaining the inherent distribution (also for correcting the bias) is proposed, an approach which includes two procedures: 1) Correcting the cumulative probabilities of orientation according to the solutions, and 2) Determining the distribution of the corrected orientations using approximation methods such as the one-sample Kolmogorov-Smirnov test. The inherent distribution corrected by the proposed method can be used for discrete fracture network (DFN) modelling, which is applied to such areas as rockmass stability evaluation, rockmass permeability analysis, rockmass quality calculation and other related fields. To maximize the correction capacity of the proposed method, the observed sample size is suggested through effectiveness tests for different distribution types, dispersions and sample sizes. The performance of the proposed method and the comparison of its correction capacity with existing methods are illustrated with two case studies.
Related Concept Videos
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...