Minimally invasive or noninvasive cardiac output measurement: an update
Lisa Sangkum1,2, Geoffrey L Liu2, Ling Yu2
1Department of Anesthesiology, Ramathibodi Hospital, Bangkok, 10400, Thailand.
Abstract:
Although cardiac output (CO) by pulmonary artery catheterization (PAC) has been an important guideline in clinical management for more than four decades, some studies have questioned the clinical efficacy of CO in certain patient populations. Further, the use of CO by PAC has been linked to numerous complications including dysrhythmia, infection, rupture of pulmonary artery, injury to adjacent arteries, embolization, pulmonary infarction, cardiac valvular damage, pericardial effusion, and intracardiac catheter knotting. The use of PAC has been steadily declining over the past two decades. Minimally invasive and noninvasive CO monitoring have been studied in the past two decades with some evidence of efficacy. Several different devices based on pulse contour analysis are available currently, including the uncalibrated FloTrac/Vigileo system and the calibrated PiCCO and LiDCO systems. The pressure-recording analytical method (PRAM) system requires only an arterial line and is commercially available as the MostCare system. Transesophageal echocardiography (TEE) can measure CO by non-Doppler- or Doppler-based methods. The partial CO2 rebreathing technique, another method to measure CO, is marketed by Novametrix Medical Systems as the NICO system. Thoracic electrical bioimpedance (TEB) and electric bioreactance (EB) are totally noninvasive CO monitoring. Nexfin HD and the newer ClearSight systems are examples of noninvasive CO monitoring devices currently being marketed by Edwards Lifesciences. The developing focus in CO monitoring devices appears to be shifting to tissue perfusion and microcirculatory flow and aimed more at markers that indicate the effectiveness of circulatory and microcirculatory resuscitations.
More Related Videos
08:01Semi-Minimal Invasive Method to Induce Myocardial Infarction in Rats and the Assessment of Cardiac Function by an Isolated Working Heart System
Published on: June 11, 2020
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...