Related Experiment Video
Updated: Mar 24, 2026

Investigating von Willebrand Factor Pathophysiology Using a Flow Chamber Model of von Willebrand Factor-platelet String Formation
Published on: August 14, 2017
Increased von Willebrand factor, P-selectin and fibrin content in occlusive thrombus resistant to lytic therapy
Antonia Sambola1, Bruno García Del Blanco, Marisol Ruiz-Meana
1Antonia Sambola, Department of Cardiology, Hospital Universitari Vall d'Hebron, P. Vall d'Hebron, 119-129, 08035 Barcelona, Spain, Tel.: +34 932746002, Fax: +34 932746063,
Therapeutic fibrinolysis is ineffective in 40 % of ST-segment elevation acute myocardial infarction (STEMI) patients, but understanding of the mechanisms is incomplete. It was our aim to compare the composition of coronary thrombus in lysis-resistant STEMI patients with that of lysis-sensitive patients. Intracoronary thrombi (n=64) were obtained by aspiration in consecutive STEMI patients. Of them, 20 had received fibrinolysis and underwent rescue percutaneous coronary intervention (r-PCI, lysis-resistant patients) and 44 underwent primary PCI (p-PCI). Lysis-sensitivity was determined in vitro by clot permeability measurements and turbidimetric lysis in plasma of 44 patients undergoing p-PCI and 20 healthy donors. Clot-lysis sensitivity was defined as a clot-lysis time not greater than 1 SD over the mean of healthy donors. Coronary thrombus composition in 20 lysis-resistant and in 20 lysis-sensitive patients was analysed by immunofluorescence with confocal microscopy. Plasma biomarkers (P-selectin, VWF, PAI-1, t-PA, D-dimer, TF pathway markers, plasmin and CD34+) were measured simultaneously on peripheral blood. Lysis-resistant clots had higher levels of fibrin (p=0.02), P-selectin (p=0.03) and VWF (p=0.01) than lysis-sensitive clots. Among thrombi obtained ≤ 6 hours after onset of symptoms, those from lysis-resistant patients showed a higher content in fibrin than those from p-PCI patients (p=0.01). Plasma PAI-1 (p=0.02) and D-dimer levels were significantly higher (p=0.003) in lysis-resistant patients, whereas plasmin levels were lower (p=0.03). Multivariate analysis showed the content of fibrin and VWF within thrombus as predictors of thrombolysis resistance. In conclusion, coronary thrombi in STEMI patients resistant to fibrinolysis are characterised by higher fibrin, P-selectin and VWF content than lysis-sensitive thrombi.
Therapeutic fibrinolysis is ineffective in 40 % of ST-segment elevation acute myocardial infarction (STEMI) patients, but understanding of the mechanisms is incomplete. It was our aim to compare the composition of coronary thrombus in lysis-resistant STEMI patients with that of lysis-sensitive patients. Intracoronary thrombi (n=64) were obtained by aspiration in consecutive STEMI patients. Of them, 20 had received fibrinolysis and underwent rescue percutaneous coronary intervention (r-PCI, lysis-resistant patients) and 44 underwent primary PCI (p-PCI). Lysis-sensitivity was determined in vitro by clot permeability measurements and turbidimetric lysis in plasma of 44 patients undergoing p-PCI and 20 healthy donors. Clot-lysis sensitivity was defined as a clot-lysis time not greater than 1 SD over the mean of healthy donors. Coronary thrombus composition in 20 lysis-resistant and in 20 lysis-sensitive patients was analysed by immunofluorescence with confocal microscopy. Plasma biomarkers (P-selectin, VWF, PAI-1, t-PA, D-dimer, TF pathway markers, plasmin and CD34+) were measured simultaneously on peripheral blood. Lysis-resistant clots had higher levels of fibrin (p=0.02), P-selectin (p=0.03) and VWF (p=0.01) than lysis-sensitive clots. Among thrombi obtained ≤ 6 hours after onset of symptoms, those from lysis-resistant patients showed a higher content in fibrin than those from p-PCI patients (p=0.01). Plasma PAI-1 (p=0.02) and D-dimer levels were significantly higher (p=0.003) in lysis-resistant patients, whereas plasmin levels were lower (p=0.03). Multivariate analysis showed the content of fibrin and VWF within thrombus as predictors of thrombolysis resistance. In conclusion, coronary thrombi in STEMI patients resistant to fibrinolysis are characterised by higher fibrin, P-selectin and VWF content than lysis-sensitive thrombi.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Clot Retraction and Fibrinolysis
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Venous Thrombosis I: Introduction
Venous Thrombosis III: Interprofessional Care

