[Gentamicin pharmacokinetics in term newborn: ¿Is it necessary to systematically monitor plasmatic levels?]
Background:
Gentamicin is indicated as empiric treatment for neonatal sepsis. Plasmatic levels dosification of gentamicin is a common practice. The relationship between peak plasma concentration (Cmáx) with minimum inhibitory concentration (MIC) (Cmáx/MIC) is the parameter that best predicts treatment efficacy.
Aim:
To determine pharmacokinetics of gentamicin in term newborn infants.
Methods:
Term newborn infants receiving gentamicin, without critical illness in which plasmatic levels of gentamicin was performed were included. Elimination clearance (Cl) elimination half-life (t½) and volume of distribution (Vd) were calculated. In each case the value of Cmax/MIC parameter was calculated, considering a MIC value of 1 μg/mL for Escherichia coli.
Results:
Thirteen newborns were included. The mean PK values were Cl: 0.26 mL/hour, Vd: 0.54 L/kg and t½: 6.8 h. Cmax/MIC was > 8 in 6 newborns.
Conclusions:
Pharmacokinetic parameters of gentamicin are predictable in term newborn infants. With gentamicin doses normally used Cmax/MIC values reached 8 in 6 newborns. It is necessary to review the usefulness of plasma drug monitoring and gentamicin dosage in this group of newborns.
Related Concept Videos
Pharmacokinetics in Pediatric Patients: Drug Metabolism
Pharmacokinetics in Pediatric Patients: Overview and Drug Absorption
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Pharmacokinetics in Pediatric Patients: Drug Excretion
Pharmacokinetics in Pediatric Patients: Drug Distribution
Estimation of k and VD of Aminoglycosides