Predictors for failure of vacuum-assisted vaginal delivery: a case-control study
Corine J Verhoeven1, Chelly Nuij2, Christel R M Janssen-Rolf3
1Department of Obstetrics & Gynecology, Maxima Medical Center, Veldhoven, The Netherlands; Department of Midwifery Science, AVAG/EMGO Institute for Health and Care Research, VU University Medical Center, Amsterdam, The Netherlands.
Objective:
To identify potential predictors for failed vacuum-assisted delivery.
Study Design:
Retrospective case-control study conducted in two perinatal centers in the Netherlands. Cases were women who underwent a failed vacuum-assisted delivery between 1997 and 2011. A failed vacuum extraction was defined as a delivery that was started as vacuum extraction but was converted to a cesarean section because of failure to progress. As controls we studied two successful vacuum extractions that were performed before the failed one. We used multivariable logistic regression to assess the risk for failed vacuum extraction.
Results:
Between 1997 and 2011, 6734 trials of vacuum extraction were performed of which 309 failed (4.6%). These 309 cases were compared to the data of 618 women who underwent a successful vacuum extraction. Predictors for failed vacuum-assisted vaginal delivery were increasing gestational age (OR 1.2 per week), maternal height (OR 0.97 per cm), previous vaginal birth as compared to nulliparae (OR 0.32), estimated fetal weight ≥3750g as compared to <3250g (OR 5.7), epidural analgesia (OR 3.0), augmentation (OR 1.4), failure to progress as indication for trial of vacuum delivery (OR 1.7), station of descent of the fetal head (OR 0.31 per station more descended), and occiput posterior position (OR 2.6). The area under the receiver-operating characteristic curve of a prediction model integrating these indicators was 0.83.
Conclusion:
Failed vacuum extraction can be predicted accurately using both ante- and intrapartum characteristics. There is a strong need for prospective studies on the subject.
Related Concept Videos
Mitral Valve Prolapse III: Nursing Management
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Factors Affecting the Risk of Infection
The integrity and count of the white blood cells help the body resist pathogens and fight infection. When impaired, it reduces the body's resistance to pathogens. The acidic pH levels of the gastrointestinal, genitourinary tracts, and skin...