Related Experiment Video
Updated: Mar 24, 2026

Human Fetal Blood Flow Quantification with Magnetic Resonance Imaging and Motion Compensation
Published on: January 7, 2021
Jacobian weighted temporal total variation for motion compensated compressed sensing reconstruction of dynamic MRI
Javier Royuela-Del-Val1, Lucilio Cordero-Grande2, Federico Simmross-Wattenberg1
1Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain.
Purpose:
To eliminate the need of spatial intraframe regularization in a recently reported dynamic MRI compressed-sensing-based reconstruction method with motion compensation and to increase its performance.
Theory And Methods:
We propose a new regularization metric based on the introduction of a spatial weighting measure given by the Jacobian of the estimated deformations. It shows convenient discretization properties and, as a byproduct, it also provides a theoretical support to a result reported by others based on an intuitive design. The method has been applied to the reconstruction of both short and long axis views of the heart of four healthy volunteers. Quantitative image quality metrics as well as straightforward visual assessment are reported.
Results:
Short and long axis reconstructions of cardiac cine MRI sequences have shown superior results than previously reported methods both in terms of quantitative metrics and of visual assessment. Fine details are better preserved due to the lack of additional intraframe regularization, with no significant image artifacts even for an acceleration factor of 12.
Conclusions:
The proposed Jacobian Weighted temporal Total Variation results in better reconstructions of highly undersampled cardiac cine MRI than previously proposed methods and sets a theoretical ground for forward and backward predictors used elsewhere. Magn Reson Med 77:1208-1215, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
More Related Videos
09:33Diffusion Tensor Magnetic Resonance Imaging in the Analysis of Neurodegenerative Diseases
Published on: July 28, 2013
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Imaging Studies for Cardiovascular System IV: CMRI
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...