Related Experiment Video
Updated: Mar 24, 2026

High-Throughput Assays of Critical Thermal Limits in Insects
Published on: June 15, 2020
Estimating the critical thermal maximum (CTmax) of bed bugs, Cimex lectularius: Comparing thermolimit respirometry
Zachary C DeVries1, Stephen A Kells2, Arthur G Appel3
1Department of Entomology and Plant Pathology, 301 Funchess Hall, Auburn University, Auburn, AL 36849, USA; Department of Entomology, Campus Box 7613, North Carolina State University, Raleigh, NC 27695-7613, USA.
Abstract:
Evaluating the critical thermal maximum (CTmax) in insects has provided a number of challenges. Visual observations of endpoints (onset of spasms, loss of righting response, etc.) can be difficult to measure consistently, especially with smaller insects. To resolve this problem, Lighton and Turner (2004) developed a new technique: thermolimit respirometry (TLR). TLR combines real time measurements of both metabolism (V·CO2) and activity to provide two independent, objective measures of CTmax. However, several questions still remain regarding the precision of TLR and how accurate it is in relation to traditional methods. Therefore, we evaluated CTmax of bed bugs using both traditional (visual) methods and TLR at three important metabolic periods following feeding (1d, 9d, and 21d). Both methods provided similar estimates of CTmax, although traditional methods produced consistently lower values (0.7-1°C lower than TLR). Despite similar levels of precision, TLR provided a more complete profile of thermal tolerance, describing changes in metabolism and activity leading up to the CTmax, not available through traditional methods. In addition, feeding status had a significant effect on bed bug CTmax, with bed bugs starved 9d (45.19[±0.20]°C) having the greatest thermal tolerance, followed by bed bugs starved 1d (44.64[±0.28]°C), and finally bed bugs starved 21d (44.12[±0.28]°C). Accuracy of traditional visual methods in relation to TLR is highly dependent on the selected endpoint; however, when performed correctly, both methods provide precise, accurate, and reliable estimations of CTmax.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

