Related Experiment Video
Updated: Mar 24, 2026

Electrochemical Preparation of Poly3,4-Ethylenedioxythiophene Layers on Gold Microelectrodes for Uric Acid-Sensing Applications
Published on: July 28, 2021
Electrode Prepared with Combination of Different Conductive Polymers for Hydroquinone Determination in River Water
Abstract:
Modified electrode based on combination of different conductive polymers (Polyaniline - Poly(3-methylthiophene) - Poly(3,3' diaminobenzidine) (PANI - P3MT - PDAB)) was previously synthesized in dichloromethane containing HClO(4) and tetrabutylammoniumperchlorate (TBAP) supporting electrolyte. In this study, determination of hydroquinone (HQ) with amperometric I-t method over this modified and its homopolymers coated electrode was successfully carried out in river water as real sample and in solution consisting of NaHSO(4)/Na(2)SO(4) (pH 2.0). For this method, potentials between 0.45 V and 0.65 V were applied and the best analytical response was obtained at 0.55 V using this modified electrode when compared its homopolymer. The limit of detection (LOD), limit of quantification (LOQ) , the linear dynamic range and regression coefficient (R(2)) were found as 1.31 x 10(-4) mM, 4.37 x 10(-4) mM, 4.37 x 10(-4)- 95.0 mM and 0.998, respectively. These results were compared to homopolymers coated and uncoated Pt electrodes. For checking on the accuracy of the developed method and the matrices interference, determination of HQ was performed in artificially contaminated river water samples with HQ concentration 5.0 mM and 10.0 mM using this modified electrode and recovery values were calculated as % 100.6 and % 100.1, respectively.
More Related Videos
09:27A Method for Systematic Electrochemical and Electrophysiological Evaluation of Neural Recording Electrodes
Published on: March 3, 2014
09:15Iridium Oxide-reduced Graphene Oxide Nanohybrid Thin Film Modified Screen-printed Electrodes as Disposable Electrochemical Paper Microfluidic pH Sensors
Published on: November 22, 2016
Related Concept Videos
Electrodeposition
Electrodeposition can...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes