Related Experiment Video
Updated: Mar 24, 2026

Mouse Model of Metabolic Dysfunction-Associated Steatotic Liver Disease with Fibrosis
Published on: July 18, 2025
Fontan-associated liver disease: Spectrum of US findings
Jung Min Bae1, Tae Yeon Jeon1, Jung Sun Kim2
1Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710, South Korea.
Purpose:
To describe ultrasonography (US) findings of Fontan-associated liver disease (FALD) and to determine whether screening US examinations can identify FALD before biochemical hepatic dysfunction.
Methods:
This retrospective study included 55 patients who underwent Fontan procedure over a 20-year period. Hepatobiliary US findings (n=55), CT or MRI findings (n=19), biochemical hepatic function tests (n=49), and histopathological results (n=4) were analyzed. Images were reviewed focusing on the hepatic parenchymal changes, presence of focal lesions, and signs of portal hypertension.
Results:
Hepatic parenchymal changes (either heterogeneous echotexture or surface nodularity) evident on US were present in 67% (37/55) and showed positive correlation with the Fontan duration. Hyper-echoic lesions were noted in 35% (19/55) and showed a predilection for multiplicity, small size, right lobe location, and irregular margin on high-frequency transducer. These lesions were not demonstrated by CT or MRI or by low-frequency transducer. Histopathological results of targeted biopsy for hyper-echoic lesions revealed lesser degree of patchy sinusoidal and portal fibrosis than seen in cases with surface nodularity. Abnormal parenchymal enhancement was commonly seen with CT or MRI in 63% (12/19) and hypervascular nodules in 21% (4/19). Most patients (82%, 40/49) showed normal biochemical hepatic function tests, despite the presence of hepatic parenchymal changes on imaging.
Conclusion:
The common US findings of FALD included heterogeneous parenchymal echotexture, surface nodularity, and hyper-echoic lesions. We suggest that hyper-echoic lesions without surface nodularity detected by high-frequency transducer may represent the early stage of fibrosis. US examination may be useful for identifying the progression of FALD before biochemical hepatic dysfunction.
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Diseases of the Liver and Gallbladder
Cirrhosis is characterized by the scarring of hepatic lobules in the liver, which are replaced by fibrous tissue, affecting the liver's normal functioning. NAFLD, on the other hand, is caused by an excessive build-up of fat in the liver, not...
Effect of Hepatic Disease on Pharmacokinetics: Pathophysiologic Assessment and Liver Function Test
Gross Anatomy of the Liver
Located under the diaphragm, the liver is almost entirely ensconced within the rib cage, providing it with substantial protection. Except for the superior most bare area, the liver's surface is...
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...
Liver Histology
Hepatocytes perform a variety of essential functions. They secrete...

