Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Continuum in MDGC Technology: From Classical Multidimensional to Comprehensive Two-Dimensional Gas Chromatography
Chadin Kulsing1, Yada Nolvachai1, Paul Rawson2
1Australian Centre for Research on Separation Science, School of Chemistry, Monash University , Wellington Road, Clayton, Victoria 3800, Australia.
Abstract:
Recent advances in multidimensional gas chromatography (MDGC) comprise methods such as multiple heart-cut (H/C) analysis and comprehensive two-dimensional gas chromatography (GC × GC); however, clear approaches to evaluate the MDGC results, choice of the most appropriate method, and optimized separation remain of concern. In order to track the capability of these analytical techniques and select an effective experimental approach, a fundamental approach was developed utilizing a time summation model incorporating temperature-dependent linear solvation energy relationship (LSER). The approach allows prediction of optimized analyte distribution in the 2D space for various MDGC approaches employing different experimental variables such as column lengths, temperature programs, and stationary phase combinations in order to evaluate separation performance (apparent (1)D, (2)D, total number of separated peaks, and orthogonality) for simulated MDGC results. The methodology applied LSER to generate results for nonpolar-polar and polar-nonpolar 2D column configurations for separation of 678 compounds in an oxidized kerosene-based jet fuel sample. Three-dimensional plots were generated in order to illustrate the dependency of separation performance on (2)D column length and number of injections for different stationary phase combinations. With a given limit of analysis time, a MDGC approach to obtain an optimized total separated peak number for a particular column set was proposed depending on (1)D and (2)D analyte peak distribution. This study introduces fundamental concepts and establishes approaches to design effective GC × GC or multiple H/C systems for different column combinations, to provide the best overall separation outcomes with the highest separated peak number and/or orthogonality.
More Related Videos
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...