Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

7.6K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
7.6K
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

4.6K
Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
4.6K
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

2.4K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
2.4K
Mass Spectrometry: Complex Analysis01:21

Mass Spectrometry: Complex Analysis

2.0K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.0K
Gas Chromatography: Types of Detectors-II01:19

Gas Chromatography: Types of Detectors-II

1.4K
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
1.4K
Gas Chromatography: Types of Detectors-I01:21

Gas Chromatography: Types of Detectors-I

1.9K
There are different types of detectors used in gas chromatography, each with its own specific properties that make it suitable for detecting certain types of analytes. The most commonly used detectors in GC are thermal conductivity detector (TCD), flame ionization detector (FID), and electron capture detector (ECD).
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
1.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Approaches to using retention indices with coupled column pressure tuning in gas chromatography.

Journal of chromatography. A·2026
Same author

Experimental Design-Based Dispersive Liquid-Liquid Microextraction with GC-FID for Determination of Polycyclic Aromatic Hydrocarbons in Surface Water.

ACS omega·2026
Same author

Prior contact lens wear reduces susceptibility of the superficially-injured cornea to bacterial adhesion.

PloS one·2026
Same author

Forward-Backward-Flushing Valve-Assisted Selectivity Tuning (FBF-VAST) for LC × LC: Principles and Demonstration of a Modulation Mechanism.

Analytical chemistry·2026
Same author

Evaluation of portable atmospheric-pressure solids analysis probe-quadrupole mass spectrometry and UPLC-MS for the rapid screening of illicit substances in human urine.

Journal of chromatography. A·2026
Same author

Vitamin D enrichment of eggs and its effects on performance and intestinal health in late-stage laying hens.

Poultry science·2025

Related Experiment Video

Updated: Mar 24, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.5K

Continuum in MDGC Technology: From Classical Multidimensional to Comprehensive Two-Dimensional Gas Chromatography.

Chadin Kulsing1, Yada Nolvachai1, Paul Rawson2

  • 1Australian Centre for Research on Separation Science, School of Chemistry, Monash University , Wellington Road, Clayton, Victoria 3800, Australia.

Analytical Chemistry
|March 15, 2016
PubMed
Summary

A new model predicts multidimensional gas chromatography (MDGC) performance, aiding in selecting optimal methods like comprehensive two-dimensional GC (GC × GC) or multiple heart-cut (H/C) analysis for better separation. This approach enhances analytical technique evaluation.

More Related Videos

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
08:22

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography

Published on: May 15, 2020

8.2K
Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Published on: March 6, 2016

9.9K

Related Experiment Videos

Last Updated: Mar 24, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
10:14

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography

Published on: September 2, 2020

5.5K
Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
08:22

Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography

Published on: May 15, 2020

8.2K
Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Published on: March 6, 2016

9.9K

Area of Science:

  • Analytical Chemistry
  • Chromatography

Background:

  • Multidimensional gas chromatography (MDGC) methods like multiple heart-cut (H/C) and comprehensive two-dimensional GC (GC × GC) offer advanced separation capabilities.
  • However, evaluating MDGC results, selecting optimal methods, and achieving efficient separations remain challenging.

Purpose of the Study:

  • To develop a fundamental approach for evaluating MDGC techniques and optimizing experimental parameters.
  • To predict analyte distribution in 2D space for various MDGC configurations and assess separation performance.

Main Methods:

  • A time summation model incorporating a temperature-dependent linear solvation energy relationship (LSER) was utilized.
  • LSER was applied to generate simulated MDGC results for nonpolar-polar and polar-nonpolar 2D column configurations.
  • Separation performance metrics including apparent (1)D, (2)D, total separated peaks, and orthogonality were evaluated.

Main Results:

  • The study predicted optimized analyte distribution for different MDGC approaches, considering variables like column lengths, temperature programs, and stationary phases.
  • Three-dimensional plots illustrated the impact of (2)D column length and injection number on separation performance for various stationary phase combinations.
  • A method was proposed to optimize the total number of separated peaks within a given analysis time based on analyte peak distribution.

Conclusions:

  • This research provides fundamental concepts and practical approaches for designing effective GC × GC or multiple H/C systems.
  • The developed methodology aids in selecting optimal column combinations and experimental conditions for superior separation outcomes.
  • The study facilitates achieving the highest number of separated peaks and/or orthogonality in complex sample analyses.