Related Experiment Video
Updated: Mar 24, 2026

Author Spotlight: Learning Systematic Bronchoscopy in a Simulation-Base Setting
Published on: June 23, 2023
Predicting Optimal Insertion Depth of a Left-sided Double-Lumen Endobronchial Tube
Wei-Lin Lin1, Chen-Hwan Cherng1
1Department of Anesthesiology, Tri-Service General Hospital and National Defense Medical Center, Taipei, Taiwan.
Objective:
Appropriate placement of the double-lumen endobronchial tube (DLT) is essential for one-lung ventilation. Several formulae based on body height (BH) have been used for estimating the optimal insertion depth of a left-sided DLT. In this study, the authors examined the following 5 formulae for accuracy of prediction: 0.11×BH+10.53 (cm) from Brodsky et al(1); 0.15×BH+3.96 (cm) from Bahk and Oh(2); 0.148×BH+3.8 (cm) from Chow et al;(3) 0.1×BH+12.5 (cm) from Takita et al(4); and 0.1977×BH - 4.2423 (cm) (authors' formula).
Design:
Single-center, retrospective, observational study.
Setting:
University hospital.
Participants:
Anesthetic records of patients older than 20 years who received one-lung ventilation using a left-sided DLT were included.
Interventions:
The patients' sex, age, body weight, BH, and the final correct insertion depth of the left-sided DLT after fiberscope verification were recorded. Linear regression and correlation were used to analyze the data.
Measurements And Main Results:
One hundred seventy anesthetic records were analyzed. The insertion depth was distributed normally in 4 groups with different BH intervals. The correlations between the correct insertion depth and all the lengths calculated using each formula were significant (p<0.001), with a similar high coefficient of determination (r = 0.809). The regression line derived from the authors' formula-0.1977×BH - 4.2423 (cm)-showed the most accuracy in predicting the correct insertion depth.
Conclusions:
The height-based formula of 170 - 29.5 - 5 - 1 (the insertion depth is 29.5 cm for patients who are 170 cm tall, and the insertion length is increased or decreased by 1 cm for every 5 cm increase or decrease in BH) modified by the equation of 0.1977×BH - 4.2423 is a useful tool to predict the optimal insertion depth in initially blind left-sided DLT insertion.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Gross Anatomy of the Lungs