Related Experiment Video
Updated: Mar 24, 2026

Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Cardiac output determination using a widely available direct continuous oxygen consumption measuring device: a
Zaher Fanari1, Matthew Grove2, Anitha Rajamanickam3
1Division of Cardiology, University of Kansas School of Medicine, Kansas City, KS, USA.
Background:
Accurate assessment of cardiac output (CO) is essential for the hemodynamic assessment of valvular heart disease. Estimation of oxygen consumption (VO2) and thermodilution (TD) are employed in many cardiac catheterization laboratories (CCL) given the historically cumbersome nature of direct continuous VO2 measurement, the "gold standard" for this technique. A portable facemask device simplifies the direct continuous measurement of VO2, allowing for relatively rapid and continuous assessment of CO.
Methods And Materials:
Thirty consecutive patients undergoing right heart catheterization had simultaneous determination of CO by both direct continuous and assumed VO2 and TD. Assessments were only made when a plateau of VO2 had occurred. All measurements of direct continuous and assumed VO2, as well as, TD CO were obtained in triplicate.
Results:
Direct continuous VO2 CO and assumed VO2 CO correlated poorly (R=0.57; ICC=0.59). Direct continuous VO2 CO and TD CO also correlated poorly (R=0.51; ICC=0.60). Repeated direct continuous VO2 CO measurements were extremely correlated and reproducible [(R=0.93; ICC=0.96) suggesting that this was the most reliable measurement of CO.
Conclusions:
CO calculated from direct continuous VO2 measurement varies substantially from both assumed VO2 and TD based CO, which are widely used in most CCL. These differences may significantly impact the CO measurements. Furthermore, continuous, rather than average, measurement of VO2 appears to give highly reproducible results.
More Related Videos
04:20Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...