Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
[Detection of Atmospheric HONO and NO₂ by Incoherent Broadband Cavity Enhanced Spectroscopy]
Abstract:
We report on the development of an optical instrument based on LED-IBBCEAS for simultaneous measurements of nitrous acid (HONO) and nitrogen dioxide (NO₂) in ambient air. The light emitting from the LED centered at 365 nm was directly focused into the cavity formed with two high reflectivity mirrors, separated by a distance of 1. 76 m. The light output of the cavity was received with a portable spectrometer. The mirror reflectivity was calibrated by absorption spectra of NO₂ and O₂-O₂. In the spectral range of 353-376 nn, the maximum mirror reflectivity was found to be 0.999 17. Detection limits (1σ) of 0.6 ppbv for HONO and 1.8 ppbv for NO₂ were achieved with an acquisition time of 120 s. In order to test the accuracy of measured results by present setup, concentrations of NO₂ were recorded during continuous 56 hours and compared with data from a NOX analyzer equipped with a blue light converter. The least-square fit lines give gradients of 1. 09 and respective intercepts of 3.45, with a linear correction factor of 0.89. The concentrations of HONO and NO₂ in indoor air were monitored, the concentrations of HONO varied from near 0 to 5.3 ppbv in 24 hours, the averaged concentration was 1. 8 ppbv, and the concentrations of NO₂ varied from 5 to 51 ppbv at the same time, the averaged concentration was 21.9 ppbv.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Molecular Spectroscopy: Absorption and Emission
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...