Related Experiment Video
Updated: Mar 24, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
High Rates of Occult Infection After Shoulder Fracture Fixation: Considerations for Conversion Shoulder Arthroplasty
Till O Klatte1, Reza Sabihi2, Daniel Guenther3
1Department of Trauma, Hand and Reconstructive Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany.
Background:
Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation.
Questions/Purposes:
This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthroplasty for failed open reduction and internal fixation (ORIF) and the need for re-operation at 4.6-year follow-up.
Methods:
Twenty-eight patients who underwent conversion to shoulder arthroplasty for any reason after fracture fixation were retrospectively reviewed in a single center. A pre-operative aspiration was done in 17 patients; all patients had intra-operative tissue sampling. All procedures were single-stage removal of hardware and performance of the arthroplasty. In cases of pre-operative positive bacterial growth, a single-stage procedure was performed according to the septic ENDO-Klinik protocol.
Results:
In 4 of 17 pre-operative joint aspirations, bacterial growth was detected; one pre-operative negative aspiration demonstrated bacterial growth in intra-operative sampling. In three of them, the infection has been validated through intra-operatively results. Pre-operative aspiration showed a sensitivity of 75% and specificity of 92% (p < 0.005) for infection. No post-operative PJIs were observed. Six revisions were performed, most commonly for aseptic loosening (two cases) and conversion of hemiarthroplasty to a reverse design (two cases).
Conclusions:
In conclusion, the risk of low-grade shoulder infection after fracture osteosynthesis may be higher than in hip and knee joints, based on limited study data. Adequate pre-operative testing is recommended to rule out occult shoulder infection in this setting.