Related Experiment Video
Updated: Mar 24, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Characterization of a GEM-based scintillation detector with He-CF4 gas mixture in clinical proton beams
D Nichiporov, L Coutinho1, A V Klyachko2
1ProCure Proton Therapy Center, Somerset, NJ, USA.
Abstract:
Accurate, high-spatial resolution dosimetry in proton therapy is a time consuming task, and may be challenging in the case of small fields, due to the lack of adequate instrumentation. The purpose of this work is to develop a novel dose imaging detector with high spatial resolution and tissue equivalent response to dose in the Bragg peak, suitable for beam commissioning and quality assurance measurements. A scintillation gas electron multiplier (GEM) detector based on a double GEM amplification structure with optical readout was filled with a He/CF4 gas mixture and evaluated in pristine and modulated proton beams of several penetration ranges. The detector's performance was characterized in terms of linearity in dose rate, spatial resolution, short- and long-term stability and tissue-equivalence of response at different energies. Depth-dose profiles measured with the GEM detector in the 115-205 MeV energy range were compared with the profiles measured under similar conditions using the PinPoint 3D small-volume ion chamber. The GEM detector filled with a He-based mixture has a nearly tissue equivalent response in the proton beam and may become an attractive and efficient tool for high-resolution 2D and 3D dose imaging in proton dosimetry, and especially in small-field applications.
More Related Videos
11:27Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
Published on: December 8, 2016
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...