Related Experiment Video
Updated: Mar 24, 2026

Optimization of the Retinal Vein Occlusion Mouse Model to Limit Variability
Published on: August 6, 2021
Intraocular metallic foreign body causing branch retinal vein occlusion
Ravi Bypareddy1, Pradeep Sagar1, Rohan Chawla1
1Dr Rajendra Prasad Centre For Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, Delhi, India.
Abstract:
We report a case of a 40-year-old man with post-traumatic cataract and an intraocular metallic foreign body (IOFB) lying on the retinal surface causing a superotemporal branch retinal vein occlusion. The case was managed using lens aspiration with pars plana vitrectomy and IOFB removal. We only found two previous reports of such a foreign body causing a vascular occlusion. The possibility of a vascular occlusion occurring due to a foreign body within or close to the optic disc is highlighted.
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Venous Thrombosis I: Introduction