Related Experiment Video
Updated: Mar 24, 2026

Author Spotlight: Ex Vivo OCT-Based Multimodal Imaging of Human Donor Eyes for Research into Age-Related Macular Degeneration
Published on: May 26, 2023
Estimation of time since death by vitreous humor hypoxanthine, potassium, and ambient temperature
T O Rognum1, S Holmen2, M A Musse1
1Department of Pediatric Forensic Medicine, Norwegian Institute of Public Health, P.O. Box 4404 Nydalen, 0403 Oslo, Norway.
Abstract:
Measurement of vitreous humor potassium (K(+)) has since the 1960s been recognized as an adjunct for estimation of time since death. In 1991 we introduced hypoxanthine (Hx) as a new marker. Furthermore we demonstrated that time since death estimation was more accurate when ambient temperature was included in the calculations, both for K(+) and for Hx. In this paper we present a refined method. The subjects consist of 132 cases with known time of death and ambient temperature. One sample from each subject was used in the calculations. Vitreous humor Hx levels were available in all subjects, while K(+) was measured in 106 of the subjects, due to insufficient volume of vitreous humor. Linear regression analysis was applied to model the correlation between vitreous humor Hx and K(+), taking the interactions with temperature into consideration. The diagrams published in 1991, which also included ambient temperature, estimated median time since death with range between the 10th and 90th percentile, whereas the linear regression analysis presented in this paper estimates mean time since death with a corresponding 95% interval of confidence. We conclude that time since death may be estimated with relatively high precision applying vitreous humor Hx and K(+) concentrations combined with ambient temperature.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Radioactive Decay and Radiometric Dating