Endovascular radiofrequency ablation. Effect on the vein diameter using the ClosureFast(®) catheter
Hernán Bauzá Moreno1, Mariana Dotta1, Roxana Katsini1
1Sector de Flebolinfología, Servicio de Cirugía General, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
Introduction:
Endovascular radiofrequency with first generation catheters was not successful due to its technical difficulty and restrictions in veins with diameters larger than 12mm. However, using the new catheter there is not enough scientific evidence to affirm that the diameter represents a technical limitation. The aim of this study was to evaluate and compare pre and post-operative venous trunks diameter, aiming at the reduction of size after 6 months with last generation catheters.
Methods:
Retrospective observational and descriptive study on a cohort of patients with insufficiency of the great saphenous vein, small saphenous vein and anterior accessory vein operated on with last generation radiofrequency catheters. The diameters were evaluated in the pre and post-operative period with ultrasound.
Results:
Between 2007 and 2014 a total of 365 ablations were performed in veins with an average diameter of 9±3.1mm showing a reduction of it after 6 months with a mean value of 5.2±0.8mm (P<.0001). Total occlusion was also observed in 100% of cases and complications such as deep vein thrombosis in 0.5% and heat-induced thrombosis in 1.1%.
Conclusions:
A significant reduction in venous diameter after endovascular treatment with the new ClosureFast(®) catheters was checked, even in veins with diameters greater than 12mm.