Agreement of infrared temporal artery thermometry with other thermometry methods in adults: systematic review
Panagiotis Kiekkas1, Nikolaos Stefanopoulos1, Nick Bakalis1
1Nursing Department, Technological Educational Institute of Western Greece, Patras, Greece.
Aims And Objectives:
To critically review and synthesise the evidence on the agreement of temporal artery thermometry with invasive and noninvasive thermometry methods in hospitalised adults.
Background:
Noninvasive thermometry methods aim at combining patient comfort and ease of use with satisfactory accuracy of temperature measurements. Infrared temporal artery thermometry is based on the detection of heat radiated from this artery in the forehead and temporal region.
Design:
Systematic literature review.
Methods:
A literature search was conducted in Pubmed, CINAHL, Cochrane Library, Web of Science and Embase. Data were extracted from twenty method-comparison studies published between 2002-2015. Methodological quality of selected studies was evaluated.
Results:
Temperature measurements of temporal artery were compared with pulmonary artery, urinary bladder, oesophageal or nasopharyngeal ones in eight studies for the whole temperature range. Accuracy and precision of temporal artery thermometry exceeded recommended levels of 0·3°C in three and six studies respectively. Likewise, in nine studies that compared temporal artery temperature measurements with oral and ear-based ones, satisfactory agreement and variability was reported in five and none of them respectively. With regard to fever and hypothermia, although specificity of temporal artery thermometers for detecting these disorders was satisfactory, their sensitivity was low.
Conclusions:
Existing evidence does not support that temporal artery thermometry can replace common invasive and noninvasive thermometry methods in adult patients.
Relevance To Clinical Practice:
Health care professionals are recommended to avoid the use of infrared temporal artery temporal artery thermometry in adults, or be cautious about the accuracy and precision of its readings, until improved devices are developed.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...