Related Experiment Video
Updated: Mar 23, 2026

The Helsinki Rat Microsurgical Sidewall Aneurysm Model
Published on: October 12, 2014
COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS
Ricardo Teixeira E Silva1, Thiago Felipe Santos Barros1, José Thomé de Carvalho1
1. Universidade de São Paulo, Faculdade de Medicina, Hospital das Clínicas, Instituto de Ortopedia e Traumatologia, São Paulo, SP, Brazil.
Objective:
The aim of this study is to compare micro-sutures commonly used in our midst.
Methods:
In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture((r)), Polysuture((r)) and Ethicon((r))). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation.
Results:
There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture((r)) group as compared to Polysuture((r)) (p ≤ 0.05). Bleeding in Microsuture((r)) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture((r)) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon((r)) group showed less tendency to myointimal proliferation than the rest. (p = 0.025).
Conclusion:
The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study.