Evaluation of Patient Tolerance and Small-Bowel Distention With a New Small-Bowel Distending Agent for Enterography
Amy B Kolbe1, Joel G Fletcher1, Adam T Froemming1
11 Division of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN 55905.
Objective:
The objective of our study was to compare a flavored beverage containing a thickening agent for enterography with a low-Hounsfield-value barium suspension for side effects, taste, subjects' willingness to repeat the drinking protocol, and small-bowel distention.
Subjects And Methods:
The following five drinking protocols were administered to 10 volunteers: 1000 mL of flavored beverage followed by 350 mL of water, 1500 mL of flavored beverage, 900 mL of low-Hounsfield-value barium suspension followed by 450 mL of water, 1350 mL of low-Hounsfield-value barium suspension followed by 150 mL of water, and 1500 mL of water. MR images were obtained 50 and 60 minutes after initiation of drinking. Subjects completed a questionnaire evaluating the side effects, the taste of the drink, and their willingness to repeat the drinking protocol. Reviewers assigned scores evaluating small-bowel distention and ranked the examinations in order of preference.
Results:
There was no significant difference in nausea or vomiting among the protocols (p = 0.20 and 0.42, respectively), but larger volumes of flavored beverage and low-Hounsfield-value barium suspension resulted in more cramping and diarrhea (p = 0.001 and 0.002, respectively). The taste of the low-Hounsfield-value barium suspension was rated the worst (p < 0.0001). The subjects' willingness to repeat the drinking protocol was highest for the 1000 mL of flavored beverage or water alone (p < 0.05). There were no significant differences in subjective small-bowel distention except that water was rated the worst by two of the three readers (p < 0.02). There was no significant difference in the diameter of the most dis-tended small bowel for any segment or reader (p > 0.23).
Conclusion:
A flavored beverage containing a thickening agent has a similar side effect profile and results in equivalent small-bowel distention compared with a low-Hounsfield-value barium suspension, but subjects rate taste and their willingness to repeat the drinking protocol higher for this new agent.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Related Concept Videos
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Drugs for Treatment of Constipation-Predominant IBS
Endoscopic Procedures III: Video Capsule Endoscopy
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...