Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Overview of the 2015 ICS Consensus Conference
X Biardeau1, S Aharony1,
1Department of Urology, Jewish General Hospital, McGill University, Montreal, Quebec, Canada.
Purpose:
The AMS800™ device is considered to be the "gold-standard" when male incontinence surgical treatment is contemplated. Despite 40 years of experience, it is still a specialized procedure with a number of challenges. Here, we present the recommendations issued from the AUS Consensus Group, regarding indications, management and follow-up AMS800™ implantation or revision.
Materials And Methods:
Under ICS auspices, an expert panel met on July 10, 2015 in Chicago, IL, USA in an attempt to reach a consensus on diverse issues related to the AMS800™ device. Participants were selected by the two co-chairs on the basis of their practice in a University hospital and their experience: number of implanted AUSs according to AMS (American Medical System Holdings Inc., Minnetonka, MN) records and/or major published articles. Topics listed were the result of a pre-meeting email brainstorming by all participants. The co-chairs distributed topics randomly to all participants, who then had to propose a statement on each topic for approval by the conference after a short evidence-based presentation, when possible.
Results:
The present recommendations, based on the most recent and relevant data available in literature as well as expert opinions, successively address multiple specific and problematic issues associated with the AMS800™ trough a 6-chapter structure: pre-operative assessment, pre operative challenges, implantation technique, post-operative care, trouble-shooting, and special populations.
Conclusion:
These guidelines undoubtedly constitute a reference document, which will help urologists to carefully select patients and apply the most adapted management to implantation, follow-up and trouble-shooting of the AMS800™. Neurourol. Urodynam. 35:437-443, 2016. © 2016 Wiley Periodicals, Inc.
More Related Videos
06:51Confocal Microscopy Reveals Cell Surface Receptor Aggregation Through Image Correlation Spectroscopy
Published on: August 2, 2018
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
International Nursing Organizations I
ICN member organizations work to advance the field of nursing and healthcare via policies, partnerships, lobbying, professional...
International Nursing Organizations II
The WHO provides expert team support, including funding, vaccines, testing, and treatment tools at the country level to fight...
Integrated Healthcare System
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Methods Of Healthcare Delivery System
Managed Care System:
The managed care system is designed to control the cost while maintaining the quality of care. The patient's care from admission to discharge is planned by the primary care provider or the case manager, also known as the gatekeeper. In a managed care system, the number of care providers is...
Ischemic Heart Disease: Overview
Atherosclerosis, the primary malefactor, orchestrates this dangerous condition. It manifests as the accumulation of fatty deposits, akin to insidious plaques, within arterial walls. As time elapses, these plaques metamorphose, hardening and...