[Usefulness of Determining Acquisition Time by True Count Rate Measurement Method for Delivery 18F-FDG PET/CT]
Shota Miura1, Satoshi Odashima
1Iwate Medical University PET·LINAC Medical Center.
Abstract:
A stable quality of delivery 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) requires suitable acquisition time, which can be obtained from an accurate true count of 18F-FDG. However, the true count is influenced by body mass index (BMI) and attenuation of 18F-FDG. In order to remove these influences, we have developed a new method (actual measurement method) to measure the actual true count rate based on sub-pubic thigh, which allows us to calculate a suitable acquisition time. In this study, we aimed to verify the acquisition count through our new method in terms of two categories: (1) the accuracy of acquisition count and (2) evaluation of clinical images using physical index. Our actual measurement method was designed to obtain suitable acquisition time through the following procedure. A true count rate of sub-pubic thigh was measured through detector of PET, and used as a standard true count rate. Finally, the obtained standard count rate was processed to acquisition time. This method was retrospectively applied to 150 patients, receiving 18F-FDG administration from 109.7 to 336.8 MBq, and whose body weight ranged from 37 to 95.4 kg. The accuracy of true count was evaluated by comparing relationships of true count, relative to BMI or to administered dose of 18F-FDG. The PET/CT images obtained by our actual measurement method were assessed using physical index. Our new method resulted in accurate true count, which was not influenced by either BMI or administered dose of 18F-FDG, as well as satisfied PET/CT images with recommended criteria of physical index in all patients.
More Related Videos
15:10A Dual Tracer PET-MRI Protocol for the Quantitative Measure of Regional Brain Energy Substrates Uptake in the Rat
Published on: December 28, 2013
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET