Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Video

Updated: Mar 23, 2026

Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity
09:38

Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity

Published on: January 31, 2025

1.1K

Calculating regional tissue volume for hyperthermic isolated limb perfusion: Four methods compared.

D Cecchin1, A Negri2, A C Frigo3

  • 1Nuclear Medicine Unit, Department of Medicine DIMED, University-Hospital of Padova, Italy.

European Journal of Surgical Oncology : the Journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology
|March 24, 2016
PubMed
Summary

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

SPINK2 in hematopoiesis and cancer: Biology and clinical implications.

Cell death discovery·2026
Same author

Evidence for the Collective Nature of Radial Flow in Pb+Pb Collisions with the ATLAS Detector.

Physical review letters·2026
Same author

Evidence for the Dimuon Decay of the Higgs Boson in pp Collisions with the ATLAS Detector.

Physical review letters·2025
Same author

Evidence for Longitudinally Polarized W Bosons in the Electroweak Production of Same-Sign W Boson Pairs in Association with Two Jets in pp Collisions at sqrt[s]=13  TeV with the ATLAS Detector.

Physical review letters·2025
Same author

Observation of tt[over ¯] Production in Pb+Pb Collisions at sqrt[s_{NN}]=5.02  TeV with the ATLAS Detector.

Physical review letters·2025
Same author

Search for Dark Matter Produced in Association with a Dark Higgs Boson in the bb[over ¯] Final State Using pp Collisions at sqrt[s]=13  TeV with the ATLAS Detector.

Physical review letters·2025

This study compared methods for calculating limb volume in hyperthermic isolated limb perfusion (HILP). Computed tomography (CT) based methods, particularly Osirix and Oncentra Masterplan, offer accurate and efficient alternatives to traditional water displacement volumetry.

Area of Science:

  • Oncology
  • Medical Imaging
  • Surgical Oncology

Background:

  • Hyperthermic isolated limb perfusion (HILP) is an alternative to amputation for extremity sarcomas and melanomas.
  • Drug dosage in HILP relies on accurate limb volume measurement.
  • Traditional water displacement volumetry (WDV) is time-consuming and difficult for certain patient groups.

Purpose of the Study:

  • To compare existing methods for regional tissue volume calculation in HILP.
  • To validate open-source software for limb volume assessment in HILP.

Main Methods:

  • A review of 22 patients with lower limb melanoma or sarcoma.
  • Limb volume calculated using WDV, tape measurements, and CT image segmentation (Osirix, Oncentra Masterplan).
Keywords:
Hyperthermic isolated limb perfusionMelanomaPET/CTVolume calculation

More Related Videos

An Open-Source Normothermic Perfusion System Designed for Research Scientists
11:23

An Open-Source Normothermic Perfusion System Designed for Research Scientists

Published on: July 18, 2025

1.4K
Porcine Normothermic Isolated Liver Perfusion
07:32

Porcine Normothermic Isolated Liver Perfusion

Published on: June 9, 2023

1.6K

Related Experiment Videos

Last Updated: Mar 23, 2026

Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity
09:38

Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity

Published on: January 31, 2025

1.1K
An Open-Source Normothermic Perfusion System Designed for Research Scientists
11:23

An Open-Source Normothermic Perfusion System Designed for Research Scientists

Published on: July 18, 2025

1.4K
Porcine Normothermic Isolated Liver Perfusion
07:32

Porcine Normothermic Isolated Liver Perfusion

Published on: June 9, 2023

1.6K

Main Results:

  • Overall concordance correlation coefficient (CCC) of 0.92 for whole limb volume calculations.
  • Near-perfect concordance (CCC = 0.99) between Osirix and Oncentra.
  • CT methods allow for reliable segmentation and tissue-specific volume analysis (bone, fat, water).

Conclusions:

  • CT-based methods provide accurate and efficient limb volume calculations for HILP.
  • Osirix and Oncentra Masterplan are validated tools for HILP volume assessment.