Related Experiment Video
Updated: Mar 23, 2026

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
Catheter Related Escherichia hermannii Sepsis in a Haemodialysis Patient
Cecilie Utke Rank1, Peter Lommer Kristensen1, Dennis Schrøder Hansen2
1Department of Cardiology, Nephrology, and Endocrinology, Nordsjællands Hospital, Hillerød, Denmark.
Abstract:
Escherichia hermannii is an extremely rare etiological agent of invasive infection, and thus, the bacterium was initially considered non-pathogenic. However, in five previously reported case reports E. hermannii has been implicated as the sole pathogen. Our case report describes blood stream infection with E. hermannii in a haemodialysis patient with persisting symptoms, high fever and inflammatory markers despite appropriate antibiotic treatment until replacement of the dialysis catheter. We suspect biofilm formation to be a crucial pathogenic feature for E. hermannii in the maintenance of an infection, which stresses the necessity of antibiotic treatment along with catheter replacement in bloodstream- and catheter-related infection with E. hermannii.
Related Concept Videos
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Hemodialysis II: Procedure and Complications
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Hemodialysis I: Introduction
Acute Kidney Injury IV: Diagnostic Studies and Prevention