Related Experiment Video
Updated: Mar 23, 2026

Detecting Somatic Genetic Alterations in Tumor Specimens by Exon Capture and Massively Parallel Sequencing
Published on: October 18, 2013
Comparison of whole-exome sequencing of matched fresh and formalin fixed paraffin embedded melanoma tumours:
Ricardo De Paoli-Iseppi1, Peter A Johansson2, Alexander M Menzies3
1Melanoma Institute Australia, North Sydney, NSW, Australia.
Abstract:
The identification of recurrent driver mutations by whole-exome sequencing (WES) of fresh-frozen human cancers and the subsequent development of novel targeted therapies have recently transformed the treatment of many cancers including melanoma. In routine clinical practice, fresh-frozen tissue is rarely available and mutation testing usually needs to be carried out on archival formalin fixed, paraffin embedded (FFPE) tissue, from which DNA is typically fragmented, cross-linked and of lower quality. In this study we aimed to determine whether WES data generated from genomic DNA (gDNA) extracted from FFPE tissues can be produced reliably and of clinically-actionable standard. In this study of ten melanoma patients, we compared WES data produced from analysis of gDNA isolated from FFPE tumour tissue with that isolated from fresh-frozen tumour tissue from the same specimen. FFPE samples were sequenced using both Illumina's Nextera and NimbleGen SeqCap exome capture kits. To examine mutations between the two tissue sources and platforms, somatic mutations in the FFPE exomes were called using the matched fresh tissue sequence as a reference. Of the 10 FFPE DNA samples, seven Nextera and four SeqCap samples passed library preparation. On average, there were 5341 and 2246 variants lost in FFPE compared to matched fresh tissue utilising Nextera and SeqCap kits, respectively. In order to explore the feasibility of future clinical implementation of WES, FFPE variants in 27 genes of important clinical relevance in melanoma were assessed. The average concordance rate was 43.2% over a total of 1299 calls for the chosen genes in the FFPE DNA. For the current clinically most important melanoma mutations, 0/3 BRAF and 6/8 (75%) NRAS FFPE calls were concordant with the fresh tissue result, which was confirmed using a Sequenom OncoCarta Panel. The poor performance of FFPE WES indicates that specialised library construction to account for low quality DNA and further refinements will be necessary before this approach could be used for routine clinical decision making over currently preferred techniques.
Insights
Whole-exome sequencing (WES) from formalin-fixed, paraffin-embedded (FFPE) melanoma tissue yields fragmented DNA, leading to significant variant loss and low concordance. Further refinements are needed for clinical application of FFPE WES.
Area of Science:
- Genomics
- Oncology
- Molecular Diagnostics
Background:
- Whole-exome sequencing (WES) of fresh-frozen cancers has driven targeted therapy development.
- Routine clinical practice relies on formalin-fixed, paraffin-embedded (FFPE) tissue, yielding lower quality DNA.
- The clinical utility of WES from FFPE tissue remains to be fully established.
Purpose of the Study:
- To evaluate the reliability and clinical-actionable standard of WES data generated from FFPE melanoma tissues.
- To compare WES data from FFPE tissue with matched fresh-frozen tissue.
- To assess the feasibility of using FFPE WES for routine clinical decision-making.
Main Methods:
- Comparison of WES data from FFPE and fresh-frozen melanoma tissues from ten patients.
- Utilized Illumina's Nextera and NimbleGen SeqCap exome capture kits for FFPE samples.
- Somatic mutations in FFPE exomes were called using matched fresh tissue as a reference.
Main Results:
- Seven of ten Nextera and four of ten SeqCap FFPE samples passed library preparation.
- Average variant loss in FFPE compared to fresh tissue was 5341 (Nextera) and 2246 (SeqCap).
- Average concordance rate for clinically relevant melanoma genes in FFPE was 43.2%; 75% for NRAS mutations but 0% for BRAF.
Conclusions:
- WES from FFPE melanoma tissue demonstrates significant challenges due to DNA fragmentation and quality issues.
- Current FFPE WES performance is insufficient for routine clinical decision-making.
- Specialized library preparation and further refinements are necessary for clinical implementation of FFPE WES.
More Related Videos
09:58DNA-barcode-based Multiplex Immunofluorescence Imaging to Analyze FFPE Specimens from Genetically Reprogrammed Murine Melanoma
Published on: June 6, 2025
13:24Integration of Wet and Dry Bench Processes Optimizes Targeted Next-generation Sequencing of Low-quality and Low-quantity Tumor Biopsies
Published on: April 11, 2016