Related Experiment Video
Updated: Mar 23, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Impact of Endotracheal Intubation on Interventional Endoscopy Unit Efficiency Metrics at a Tertiary Academic Medical
Yaseen B Perbtani1, Robert J Summerlee2, Dennis Yang2
1Department of Medicine, University of Florida, Gainesville, Florida, USA.
Objectives:
Measures for evaluating interventional endoscopy unit efficiency have not been adequately validated, especially in reference to the involvement of anesthesia services for endoscopy. Primary aim was to compare process measures/metrics of interventional endoscopy unit efficiency between intubated and non-intubated patients. Secondary aim was to assess variables associated with the need for endotracheal intubation.
Methods:
The prospectively collected endoscopy unit metrics database at UF Health was reviewed for procedures performed in the interventional endoscopy unit for 6 months. Parameters included hospital-mandated metrics available from the database.
Results:
A total of 1,421 patients underwent 1,635 interventional endoscopic procedures and 271/1,421 patients (19.1%) were intubated. There was no significant difference between intubated and non-intubated cohorts with respect to age, gender, BMI, ASA Score, Mallampati Score, or the Charlson Comorbidity Index. Patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) were more frequently intubated than those undergoing non-ERCP procedures (41.3 vs. 12.4%, P<0.0001). Inpatients comprised 48.3% of all intubated patients, whereas only 29.2% of non-intubated patients were inpatients (P<0.0001). Most patients (159/271, 58.7%) were intubated per anesthesiologist preference. All process efficiency metrics were significantly prolonged in the intubated compared with the non-intubated patient cohort, except the time interval between successive procedures. Multivariate analysis revealed that patients with an anesthesiologist who had performed a greater number of total endoscopic sedations were less likely to be intubated than patients with an anesthesiologist who had performed fewer total procedures (P=0.0066).
Conclusions:
Endotracheal intubation negatively impacts efficiency metrics in an interventional endoscopy unit. Careful assessment for the need for intubation should be emphasized.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

