Related Experiment Video
Updated: Mar 23, 2026

Formation of Covalent DNA Adducts by Enzymatically Activated Carcinogens and Drugs In Vitro and Their Determination by 32P-postlabeling
Published on: March 20, 2018
Iodine-125-labeled DNA-Triplex-forming oligonucleotides reveal increased cyto- and genotoxic effectiveness compared
Volker Dahmen1, Ekkehard Pomplun1, Ralf Kriehuber1
1a Radiation Biology Unit, Department of Safety and Radiation Protection , Forschungszentrum Jülich GmbH , Jülich , Germany.
Purpose:
The efficacy of DNA-targeting radionuclide therapies might be strongly enhanced by employing short range particle-emitters. However, the gain of effectiveness is not yet well substantiated. We compared the Auger electron emitter I-125 to the ß--emitter P-32 in terms of biological effectiveness per decay and radiation dose when located in the close proximity to DNA using DNA Triplex-forming oligonucleotides (TFO). The clonogenicity and the induction of DNA double-strand breaks (DSB) were investigated in SCL-II cells after exposure to P-32- or I-125-labeled TFO targeting the glyceraldehyde 3-phosphate dehydrogenase (GAPDH) gene and after external homogeneous exposure to gamma-rays as reference radiation.
Materials And Methods:
TFO were labeled with P-32 or I-125 using the primer extension method. Cell survival was analyzed by colony-forming assay and DNA damage was assessed by microscopic quantification of protein 53 binding protein 1 (53BP1) foci in SCL-II cells.
Results:
I-125-TFO induced a pronounced decrease of cell survival (D37 at ∼360 accumulated decays per cell, equivalent to 1.22 Gy cell nucleus dose) and a significant increase of 53BP1 foci with increasing decays. The P-32-labeled TFO induced neither a strong decrease of cell survival nor an increase of 53BP1 foci up to ∼4000 accumulated decays per cell, equivalent to ∼1 Gy cell nucleus dose. The RBE for I-125-TFO was in the range of 3-4 for both biological endpoints.
Conclusions:
I-125-TFO proved to be much more radiotoxic than P-32-TFO per decay and per unit dose although targeting the same sequence in the GAPDH gene. This might be well explained by the high number of low energy Auger electrons emitted by I-125 per decay, leading to a high ionization density in the immediate vicinity of the decay site, probably producing highly complex DNA lesions overcharging DNA repair mechanisms.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Maxam-Gilbert Sequencing
Challenges of the Maxam-Gilbert Method
The...

