Background:
Concerns about alarm fatigue prompted The Joint Commission to issue a Sentinel Event Alert urging hospitals to minimize alarms. We previously conducted a quality improvement project on a single unit that reduced time on continuous pulse oximetry, a common source of physiologic monitor alarms, for patients with wheezing (ie, asthma and bronchiolitis, wheezing-associated respiratory infections).
Objective:
To study the impact of our improvement work on overall physiologic monitor alarm frequency for these patients.
Methods:
This was a retrospective cohort study at a freestanding children's hospital over an 8-week period. We compared alarm count, including respiratory, cardiac, and pulse oximetry alarms, for patients admitted to the intervention unit with the alarm count for similar patients on a control unit by using the Wilcoxon rank sum test. We used negative binomial regression to evaluate differences in alarm count between the units, adjusting for age, medical comorbidity, and length of stay.
Results:
There were 101 patients on the intervention unit and 46 patients on the control unit. The percentage of patients with medical comorbidities was significantly higher on the intervention unit (P=.01). Median alarm count per day for patients on the intervention unit was lower; however, this difference was not statistically significant (71 vs 76 alarms per patient-day, P=.29). The multivariable model estimated a nonsignificant 6.4-count decrease in alarms for patients on the intervention unit.
Conclusions:
Reducing continuous pulse oximetry use alone may not make substantial reductions in overall alarm counts. Even on our intervention unit, alarm burden remained quite high.
More Related Videos
07:51Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...
Special considerations while measuring pulse