Ambulatory blood pressure reduction following high-intensity interval exercise performed in water or dryland
Philippe Sosner1, Mathieu Gayda2, Olivier Dupuy3
1Laboratory MOVE (EA 6314), Faculty of Sport Sciences, University of Poitiers, Poitiers, France; Cardiology Department, University Hospital of Poitiers, Poitiers, France; Sports Medicine Centre "Mon Stade", Paris, France; Cardiovascular Prevention and Rehabilitation Center (ÉPIC), Montreal Heart Institute, Montreal, Quebec, Canada; Research Center, Montreal Heart Institute and University of Montreal, Montreal, Quebec, Canada; Department of Medicine, University of Montreal, Montreal, Quebec, Canada.
Abstract:
We aimed to compare blood pressure (BP) responses following moderate-intensity continuous exercise (MICE), high-intensity interval exercise (HIIE) in dry land or HIIE in immersed condition, using 24-hour ambulatory BP monitoring. Forty-two individuals (65 ± 7 years, 52% men) with a baseline BP ≥ 130/85 mm Hg (systolic/diastolic blood pressures [SBP/DBP]) were randomly assigned to perform one of the three following exercises on a stationary cycle: MICE (24 minutes at 50% peak power output) or HIIE in dry land (two sets of 10 minutes with phases of 15 seconds 100% peak power output interspersed by 15 seconds of passive recovery) or HIIE in up-to-the-chest immersed condition. While MICE modified none of the 24-hour average hemodynamic variables, dryland HIIE induced a 24-hour BP decrease (SBP: -3.6 ± 5.7/DBP: -2.8 ± 3.0 mm Hg, P < .05) and, to a much greater extent, immersed HIIE (SBP: -6.8 ± 9.5/DBP: -3.0 ± 4.5 mm Hg, P < .05). The one condition that modified 24-hour pulse-wave velocity was immersed HIIE (-0.21 ± 0.30 m/s, P < .05).
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement