Related Experiment Video
Updated: Mar 23, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
A capillary electrophoresis system with dual capacitively coupled contactless conductivity detection and electrospray
Kelliton José Mendonça Francisco1, Claudimir Lucio do Lago1
1Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, São Paulo - SP, CEP, Brazil.
Abstract:
A commercial system that is comprised of a CE coupled to an ESI triple quadrupole mass spectrometer was equipped with two capacitively coupled contactless conductivity detectors (C(4) Ds). The first C(4) D was positioned inside the original cartridge, and the second C(4) D was positioned as close as possible to the ESI probe entrance by using a 3D-printed support. The C(4) Ds electropherograms were matched to the ESI-MS electropherogram by correcting their timescales by the factor LT /LD , where LT and LD are the total capillary length and the length until the C(4) D, respectively. A general approach for method development supporting the simultaneous conductivity and MS detection is discussed, while application examples are introduced. These examples include the use of C(4) D as a simple device that dismiss the use of an EOF marker, a low-selectivity detector that continuously provide information about unexpected features of the sample, and even a detector that can be more sensitive than ESI-MS. The C(4) D used in this setup proved to have a smaller contribution to the peak broadening than ESI-MS, which allowed that a C(4) D, positioned at 12 cm from the inlet of an 80-cm-long capillary, could be used to foresee position and shape of the peaks being formed 6.8 times slower at the ESI-MS electropherogram.
More Related Videos
07:46Sheathless Capillary Electrophoresis–Mass Spectrometry for Metabolic Profiling of Biological Samples
Published on: October 1, 2016
07:54Capillary Electrophoresis Mass Spectrometry Approaches for Characterization of the Protein and Metabolite Corona Acquired by Nanomaterials
Published on: October 27, 2020
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...