Comparison of QT Interval Readings in Normal Sinus Rhythm Between a Smartphone Heart Monitor and a 12-Lead ECG for
Paul Garabelli1, Stavros Stavrakis1, Michael Albert1
1Section of Cardiovascular Diseases and Heart Rhythm Institute, University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma, USA.
Introduction:
A variety of medications ranging from antiarrhythmics to psychotropics, as well as conditions such as bradycardia, can prolong the QT interval, increasing the risk for life-threatening arrhythmias. Monitoring the corrected QT interval (QTc) is therefore critical for patient safety. The recent development of smart phone heart monitors (SHM) may allow for easier QTc monitoring. We sought to evaluate the accuracy of an SHM for assessing the QTc, as compared to the standard 12-lead ECG.
Methods And Results:
We compared the QTc interval in lead-I and lead-II between an SHM and 12-lead ECG. Healthy volunteers and hospitalized patients in sinus rhythm being loaded on dofetilide or sotalol were included. Manual and automatic measurements were studied. Across 99 healthy volunteers, the SHM QTc demonstrated good agreement (bias = 4 milliseconds, standard deviation of bias = 11 milliseconds) compared to the 12-lead ECG, using the Bland-Altman method of agreement. Across all hospitalized patients, the SHM was capable of demonstrating QTc prolongation. Between the 12-lead ECG and SHM, lead-I measurements had reasonable agreement (bias = 3 milliseconds, standard deviation of bias = 46 milliseconds). A QTc of > 500 milliseconds was associated with a higher likelihood (OR = 12.0; 95% CI 1.5-111.4; P = 0.02) to not achieve perfect agreement.
Conclusion:
The SHM is accurate in measuring QTc interval in sinus rhythm when compared to 12-lead ECG in healthy volunteers. For patients receiving QT prolonging antiarrhythmics, SHM is capable of detecting QTc prolongation, and lead-I of the SHM is most accurate in measuring the QTc if < 500 milliseconds.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Holter Monitor: 24-Hour Monitoring
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...