Related Experiment Video
Updated: Mar 23, 2026

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
How to evaluate BP measurements using the oscillometric method in atrial fibrillation: the value of pulse rate
Xi-Xing Wang1, Wei Shuai1, Kui Hong1
1Department of Cardiology, the Second Affiliated Hospital of Nanchang University, Jiangxi, China.
Abstract:
An oscillometric device is recommended for blood pressure (BP) measurement in atrial fibrillation (AF), but there is still controversy concerning its accuracy. Therefore, evaluation of BP values in AF patients remains a challenge. This study included 251 patients with AF and 154 participants with sinus rhythm (SR). Pulse rate (PR) and BP were measured using an oscillometric device three times. The differences between the highest and lowest PR and the systolic and diastolic BP (SBP and DBP) were calculated as ΔPR, ΔSBP and ΔDBP, respectively. AF patients were stratified with respect to ΔPR in 0-5, 6-10, 11-15 and >15 subgroups. The AF group had a greater ΔPR (12.1±8.6 vs. 4.10±3.21 b.p.m., P<0.001), ΔSBP and ΔDBP than the SR group at similar SBP and DBP. A positive correlation existed between ΔPR and ΔSBP (r=0.255, P<0.001) in AF patients, but no correlation was found in SR subjects. Meanwhile, the ΔSBP in the 0-5 and 6-10 subgroups (9.58±5.61 and 10.67±6.77 vs. 8.45±5.25 mm Hg, nonsignificant) was similar to the SR group, whereas ΔSBP in the 11-15 and >15 subgroups was significantly greater than the SR group. Regardless of ΔPR, the ΔDBP in the AF group was significantly greater than that of the SR group. The AF patients who exhibited greater variability in their PR also had a greater variability in their SBP readings. The SBP measurement for AF patients is accurate as the measurement for patients with SR if the ΔPR is of 0-10 b.p.m. in AF.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: