Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

15.1K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
15.1K
Transmission Electron Microscopy01:15

Transmission Electron Microscopy

7.8K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
7.8K
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

16.5K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
16.5K
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

3.0K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
3.0K
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

13.7K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
13.7K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.2K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Morphology prediction of small nanoparticles in any orientation from single electron micrographs.

npj computational materials·2026
Same author

Author Correction: Operando monitoring of the functional role of tetrahedral cobalt centers for the oxygen evolution reaction.

Nature communications·2026
Same author

Ligand-Engineered Methylammonium Lead Bromide Nanoplatelets: Single-Photon Emission and Strong Light-Matter Coupling.

ACS nano·2026
Same author

Single atoms of indium on hafnia enable superior CO<sub>2</sub>-based methanol synthesis.

Nature nanotechnology·2026
Same author

Dynamics and Control of Dual Active Sites in Co-Substituted Ni Coordination Polymers for Enhanced Oxygen Evolution Catalysis.

Journal of the American Chemical Society·2026
Same author

In Situ Liquid-Cell Transmission Electron Microscopy Insights Into Lithium-Ion Battery Materials Degradation: Challenges and Emerging Solutions.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026

Related Experiment Video

Updated: Mar 23, 2026

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope
10:25

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope

Published on: September 14, 2018

10.7K

Coherent Chromatic Effect in the Transmission Electron Microscope.

Rolf Erni1

  • 1Electron Microscopy Center, Empa-Swiss Federal Laboratories for Materials Science and Technology, CH-8600 Dübendorf, Switzerland.

Physical Review Letters
|April 2, 2016
PubMed
Summary

Elastic electron scattering causes energy loss, especially for light elements at high resolution. This effect, though small, impacts image contrast in transmission electron microscopy but can be used to improve light atom visibility.

More Related Videos

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon
08:18

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon

Published on: June 16, 2020

8.1K
Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
07:50

Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization

Published on: July 17, 2015

11.7K

Related Experiment Videos

Last Updated: Mar 23, 2026

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope
10:25

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope

Published on: September 14, 2018

10.7K
High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon
08:18

High-Accuracy Correction of 3D Chromatic Shifts in the Age of Super-Resolution Biological Imaging Using Chromagnon

Published on: June 16, 2020

8.1K
Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization
07:50

Electron Channeling Contrast Imaging for Rapid III-V Heteroepitaxial Characterization

Published on: July 17, 2015

11.7K

Area of Science:

  • Physics
  • Materials Science
  • Electron Microscopy

Background:

  • Elastic electron scattering at finite angles causes energy loss.
  • This energy loss is typically negligible in conventional transmission electron microscopy (TEM).
  • Sub-Ångström resolution imaging of light elements significantly increases this energy loss.

Purpose of the Study:

  • To investigate the element-specific chromatic effect of finite energy loss in high-resolution TEM.
  • To analyze how this effect depends on instrument resolution and atomic mass.
  • To explore the implications for image contrast and potential optimization strategies.

Main Methods:

  • Theoretical analysis of elastic electron scattering.
  • Modeling of energy loss effects in TEM with chromatic aberration.
  • Simulation of image contrast for light and heavy elements.

Main Results:

  • Energy loss increases by over two orders of magnitude for light elements at sub-Ångström resolution.
  • The element-specific chromatic effect is more pronounced with higher instrument resolution and lower atomic mass.
  • This effect can degrade image contrast but offers opportunities for optimization.

Conclusions:

  • Finite energy loss in electron scattering is a critical factor for high-resolution imaging of light elements.
  • The element-specific chromatic effect must be considered for accurate contrast interpretation.
  • This phenomenon can be leveraged to enhance the contrast of light atoms against heavy atom backgrounds.