Related Experiment Video
Updated: Mar 23, 2026

An R-Based Landscape Validation of a Competing Risk Model
Published on: September 16, 2022
Comparison of Calipers for Matching on the Disease Risk Score
Abstract:
Previous studies have compared calipers for propensity score (PS) matching, but none have considered calipers for matching on the disease risk score (DRS). We used Medicare claims data to perform 3 cohort studies of medication initiators: a study of raloxifene versus alendronate in 1-year nonvertebral fracture risk, a study of cyclooxygenase 2 inhibitors versus nonselective nonsteroidal antiinflammatory medications in 6-month gastrointestinal bleeding, and a study of simvastatin + ezetimibe versus simvastatin alone in 6-month cardiovascular outcomes. The study periods for each cohort were 1998 through 2005, 1999 through 2002, and 2004 through 2005, respectively. In each cohort, we calculated 1) a DRS, 2) a prognostic PS which included the DRS as the independent variable in a PS model, and 3) the PS for each patient. We then nearest-neighbor matched on each score in a variable ratio and a fixed ratio within 8 calipers based on the standard deviation of the logit and the natural score scale. When variable ratio matching on the DRS, a caliper of 0.05 on the natural scale performed poorly when the outcome was rare. The prognostic PS did not appear to offer any consistent practical benefits over matching on the DRS directly. In general, logit-based calipers or calipers smaller than 0.05 on the natural scale performed well when DRS matching in all examples.
More Related Videos
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Relative Risk
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Pre-Procedural Guidelines for Assessing Blood Pressure
Receiver Operating Characteristic Plot
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.