Related Experiment Video
Updated: Mar 23, 2026

Technical Approach for Infrared Tracking for Soft Tissue Navigation with a Holographic Head-Mounted Display and Preclinical Validation
Published on: September 2, 2025
Combined 2D and 3D tracking of surgical instruments for minimally invasive and robotic-assisted surgery
Xiaofei Du1, Maximilian Allan2, Alessio Dore3
1Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK. xiaofei.du.13@ucl.ac.uk.
Purpose:
Computer-assisted interventions for enhanced minimally invasive surgery (MIS) require tracking of the surgical instruments. Instrument tracking is a challenging problem in both conventional and robotic-assisted MIS, but vision-based approaches are a promising solution with minimal hardware integration requirements. However, vision-based methods suffer from drift, and in the case of occlusions, shadows and fast motion, they can be subject to complete tracking failure.
Methods:
In this paper, we develop a 2D tracker based on a Generalized Hough Transform using SIFT features which can both handle complex environmental changes and recover from tracking failure. We use this to initialize a 3D tracker at each frame which enables us to recover 3D instrument pose over long sequences and even during occlusions.
Results:
We quantitatively validate our method in 2D and 3D with ex vivo data collected from a DVRK controller as well as providing qualitative validation on robotic-assisted in vivo data.
Conclusions:
We demonstrate from our extended sequences that our method provides drift-free robust and accurate tracking. Our occlusion-based sequences additionally demonstrate that our method can recover from occlusion-based failure. In both cases, we show an improvement over using 3D tracking alone suggesting that combining 2D and 3D tracking is a promising solution to challenges in surgical instrument tracking.