Related Experiment Video
Updated: Mar 23, 2026

Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025
Prosthetic Complications and Maintenance Requirements in Locator-attached Implant-Supported Overdentures: A
Abstract:
Retrospective data of 32 patients supplied with implant-supported and Locator-attached overdentures were screened for prosthetic complications and maintenance requirements, which were recorded and statistically analyzed. Mean observation time was 4.78 ± 1.72) years. Loss of retention was the most frequently observed event (n = 22). Damage and exchange of the insert holders (n = 4) and loosening of locator attachments (n = 2) and fracture of the insert holder (n = 2) were uncommon events; no loss of locator attachments was observed. Loss of retention in Locator-attached overdentures is frequent; correlating patient-specific parameters with prosthetic complications is necessary to define recommendations for the use of Locator attachments.