A comparison of the tissue oxygenation achieved using different oxygen delivery devices and flow rates
Abstract:
Consistent with the Committee on Publication Ethics guidelines, we the above authors are initiating a partial retraction of our paper: Blake DF, Naidoo P, Brown LH, Young DA, Lippmann J: A comparison of the tissue oxygenation achieved using different oxygen delivery devices and flow rates. Diving Hyperb Med. 2015;45:79-83. We wish to make the following statement: "The authors voluntarily retract aspects of this article after discovering a critical error associated with the instrumentation used in the study, namely the fitting of incorrect sensor membranes on the electrodes of the transcutaneous oximetry device used in the study. This resulted in transcutaneous oxygen tension (PtcO₂) measurements that were consistently lower than those that would be recorded with the correct electrode membranes in place. This measurement error was consistent across all arms of the study. This non-differential information error would have created a bias toward the null hypothesis. Therefore, whilst the absolute values for the data were incorrect, the direction and implications of the significant associations reported in this study are unchanged."
More Related Videos
06:26Author Spotlight: Advancing Eye Physiology Research via a Multi-Channel Flow Culture for Optimal Tissue Maintenance and Real-Time Assessment
Published on: July 14, 2023
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...